isxModularDistSysVoltage
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.22.4.1
Object
node
No description available.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.22.4.1- Type
- node
- Parent
- isxModularDistTotals
- Siblings
- 2
- Children
- 15
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| isxModularDistSysCurrent | node | - | .1.3.6.1.4.1.318.1.1.22.4.2 |
| isxModularDistSysPower | node | - | .1.3.6.1.4.1.318.1.1.22.4.3 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| isxModularDistSysOutputVoltageNominalLineToNeutral mandatory The nominal line-to-neutral voltage available at the distribution panel. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.1.1 |
| isxModularDistSysOutputVoltageAlarmMinEnable mandatory Enable or disable minimum voltage alarm generation for the distribution panel. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.1.10 |
| isxModularDistSysOutputVoltageAlarmLowEnable mandatory Enable or disable low voltage alarm generation for the distribution panel. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.1.11 |
| isxModularDistSysOutputVoltageAlarmHighEnable mandatory Enable or disable high voltage alarm generation for the distribution panel. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.1.12 |
| isxModularDistSysOutputVoltageAlarmMaxEnable mandatory Enable or disable maximum voltage alarm generation for the distribution panel. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.1.13 |
| isxModularDistSysOutputVoltageFrequencyTolerance mandatory The circuit panel output frequency tolerance in Hertz.
When the system output frequency deviates from the nominal by more than this range,
a critical alarm will be generated. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.1.14 |
| isxModularDistSysVoltageTable mandatory Allows for getting the system output voltage information. | table | - | .1.3.6.1.4.1.318.1.1.22.4.1.15 |
| isxModularDistSysOutputVoltageNominalLineToLine mandatory The nominal line-to-line voltage available at the distribution panel. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.1.2 |
| isxModularDistSysOutputNominalFrequency mandatory The nominal system output frequency. Measured in tenths of Hertz. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.1.3 |
| isxModularDistSysOutputFrequency mandatory The system output frequency in tenths of Hertz.
-1 if not available. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.1.4 |
| isxModularDistSysOutputVoltageMonitoring mandatory Indicates whether or not output voltage alarm generation is present. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.1.5 |
| isxModularDistSysOutputVoltageThresholdMin mandatory When the line-to-neutral voltage of any phase drops below this value a critical alarm will exist.
Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNomi… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.1.6 |
| isxModularDistSysOutputVoltageThresholdLow mandatory When the line-to-neutral voltage of any phase drops below this value a warning alarm will exist.
Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNomin… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.1.7 |
| isxModularDistSysOutputVoltageThresholdHigh mandatory When the line-to-neutral voltage of any phase exceeds this value a warning alarm will exist.
Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalLi… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.1.8 |
| isxModularDistSysOutputVoltageThresholdMax mandatory When the line-to-neutral voltage of any phase exceeds this value a critical alarm will exist.
Specified as a percent of the nominal voltage, isxModularDistSysOutputVoltageNominalL… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.1.9 |