isxModularDistSysCurrentTable
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.22.4.2.11
Object
table
mandatory
Allows for getting the total system phase current information.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.22.4.2.11- Type
- table
- Status
- mandatory
- Parent
- isxModularDistSysCurrent
- Siblings
- 10
- Children
- 1
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| isxModularDistSysCurrentRating mandatory The 100 percent current rating of the distribution panel. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.2.1 |
| isxModularDistSysCurrentAlarmMaxEnable mandatory Enable or disable maximum total output current alarm generation. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.2.10 |
| isxModularDistSysCurrentMonitoring mandatory Indicates whether or not total output current measurements and alarm generation are present. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.2.2 |
| isxModularDistSysCurrentThresholdMin mandatory When total system current in any phase drops below this value a critical alarm will exist.
Specified as a percent of the panel rating, isxModularDistSysCurrentRating.
A value of -… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.2.3 |
| isxModularDistSysCurrentThresholdLow mandatory When total system current in any phase drops below this value a warning alarm will exist.
Specified as a percent of the panel rating, isxModularDistSysCurrentRating.
A value of -1… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.2.4 |
| isxModularDistSysCurrentThresholdHigh mandatory When total system current in any phase exceeds this value a warning alarm will exist.
Specified as a percent of the panel rating, isxModularDistSysCurrentRating.
A value of -1 ind… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.2.5 |
| isxModularDistSysCurrentThresholdMax mandatory When total system current in any phase exceeds this value a critical alarm will exist.
Specified as a percent of the panel rating, isxModularDistSysCurrentRating.
A value of -1 in… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.22.4.2.6 |
| isxModularDistSysCurrentAlarmMinEnable mandatory Enable or disable minimum total output current alarm generation. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.2.7 |
| isxModularDistSysCurrentAlarmLowEnable mandatory Enable or disable low total output current alarm generation. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.2.8 |
| isxModularDistSysCurrentAlarmHighEnable mandatory Enable or disable high total output current alarm generation. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.22.4.2.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| isxModularDistSysCurrentEntry mandatory An entry containing data for an individual system output phase. | row | - | .1.3.6.1.4.1.318.1.1.22.4.2.11.1 |