isxModularDistModuleOutputKwhResetDate
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.22.2.6.1.23
Object
The date that the kWh usage was reset, in the format mm/dd/yyyy. Example: 01/01/2000.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.22.2.6.1.23- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- isxModularDistModuleOutputEntry
- Table
- isxModularDistModuleOutputTable
- Siblings
- 22
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| isxModularDistModuleOutputModIndex mandatory The number of the distribution module supplying power to the load equipment. | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.1 |
| isxModularDistModuleOutputThresholdLow mandatory When the current drops below this value a warning alarm will exist. | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.10 |
| isxModularDistModuleOutputThresholdHigh mandatory When the current exceeds this value a warning alarm will exist. | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.11 |
| isxModularDistModuleOutputThresholdMax mandatory When the current exceeds this value a critical alarm will exist. | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.12 |
| isxModularDistModuleOutputAlarmMinEnable mandatory Enable or disable minimum current alarm generation for this distribution cable. | column | Enumeration | .1.3.6.1.4.1.318.1.1.22.2.6.1.13 |
| isxModularDistModuleOutputAlarmLowEnable mandatory Enable or disable low current alarm generation for this distribution cable. | column | Enumeration | .1.3.6.1.4.1.318.1.1.22.2.6.1.14 |
| isxModularDistModuleOutputAlarmHighEnable mandatory Enable or disable high current alarm generation for this distribution cable. | column | Enumeration | .1.3.6.1.4.1.318.1.1.22.2.6.1.15 |
| isxModularDistModuleOutputAlarmMaxEnable mandatory Enable or disable maximum current alarm generation for this distribution cable. | column | Enumeration | .1.3.6.1.4.1.318.1.1.22.2.6.1.16 |
| isxModularDistModuleOutputCableLength mandatory The length of this distribution cable. Specified in tenths of meters. | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.17 |
| isxModularDistModuleOutputConnectorType mandatory A string describing the connector on the end of this distribution cable. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.2.6.1.18 |
| isxModularDistModuleOutputAvailableVoltages mandatory This is a bit map representing the voltages that are available at the connector.
6 bits are used to indicate the following:
b0 - L1
b1 - L2
b2 - L3
b3 - L1-… | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.19 |
| isxModularDistModuleOutputNumCables mandatory The number of distribution cables provided by this module. | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.2 |
| isxModularDistModuleOutputTotalPower mandatory The total power being consumed by the load equipment supplied by this distribution cable.
Measured in tenths of kW. | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.20 |
| isxModularDistModuleOutputKwhUsage mandatory The total energy consumed by the load equipment fed by this distribution cable.
This is the total since the date specified in the isxModularDistModuleOutputKwhResetDate
OID, and m… | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.21 |
| isxModularDistModuleOutputKwhReset mandatory Writing yes to this OID will reset the total kWh usage shown
in the isxModularDistModuleOutputKwhUsage OID. | column | Enumeration | .1.3.6.1.4.1.318.1.1.22.2.6.1.22 |
| isxModularDistModuleOutputCordIndex mandatory The index of an individual distribution cable supplied by this module. | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.3 |
| isxModularDistModuleOutputName mandatory A string describing the load equipment being supplied by this distribution cable. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.2.6.1.4 |
| isxModularDistModuleOutputLocation mandatory A string describing the location of equipment being supplied by distribution cable. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.22.2.6.1.5 |
| isxModularDistModuleOutputStatus mandatory This reflects the worse case severity for alarms associated with this distribution cable.
A value of notPresent indicates that the cable does not exist for this module.
A value of… | column | Enumeration | .1.3.6.1.4.1.318.1.1.22.2.6.1.6 |
| isxModularDistModuleOutputAlarmGeneration mandatory Enable or disable all alarm generation related to this distribution cable. | column | Enumeration | .1.3.6.1.4.1.318.1.1.22.2.6.1.7 |
| isxModularDistModuleOutputBreakerMap mandatory This is a bit map representing the breaker poles within the
module that are associated with this distribution cable.
The following 3 bits are used to indicate the indices of
the b… | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.8 |
| isxModularDistModuleOutputThresholdMin mandatory When the current drops below this value a critical alarm will exist. | column | Integer32 | .1.3.6.1.4.1.318.1.1.22.2.6.1.9 |