iemStatusProbeTempUnits
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.5
Object
column
mandatory
Enumeration
The temperature scale used to display the temperature thresholds of the probe, Celsius(1) or Fahrenheit(2). This setting is based on the system preferences configuration in the agent.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.10.2.3.2.1.5- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- iemStatusProbesEntry
- Table
- iemStatusProbesTable
- Siblings
- 14
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | celsius |
2 | fahrenheit |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| iemStatusProbeNumber mandatory The index of the probe. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.1 |
| iemStatusProbeLowHumidViolation mandatory The low humidity violation status of the probe humidity
reading. This OID will show a lowTempViolation(2)
if the current humidity reading shown in the
'iemStatusProbeCurrentHumid'… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.10 |
| iemStatusProbeMaxTempViolation mandatory The max temperature violation status of the probe
temperature reading. This OID will show a maxTempViolation(2)
if the current temperature reading shown in the
'iemStatusProbeCurr… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.11 |
| iemStatusProbeMinTempViolation mandatory The minimum temperature violation status of the probe
temperature reading. This OID will show a minTempViolation(2)
if the current temperature reading shown in the
'iemStatusProbe… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.12 |
| iemStatusProbeMaxHumidViolation mandatory The maximum humidity violation status of the probe humidity
reading. This OID will show a maxTempViolation(2)
if the current humidity reading shown in the
'iemStatusProbeCurrentHu… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.13 |
| iemStatusProbeMinHumidViolation mandatory The minimum humidity violation status of the probe humidity
reading. This OID will show a minTempViolation(2)
if the current humidity reading shown in the
'iemStatusProbeCurrentHu… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.14 |
| iemStatusProbeLocation mandatory A descriptive location for the probe set by the user. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.15 |
| iemStatusProbeName mandatory A descriptive name for the probe set by the user. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.2 |
| iemStatusProbeStatus mandatory The connected status of the probe, either
disconnected(1) or connected(2). | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.3 |
| iemStatusProbeCurrentTemp mandatory The current temperature reading from the probe displayed
in the units shown in the 'iemStatusProbeTempUnits' OID
(Celsius or Fahrenheit). | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.4 |
| iemStatusProbeCurrentHumid mandatory The current humidity reading from the probe in percent
relative humidity. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.6 |
| iemStatusProbeHighTempViolation mandatory The high temperature violation status of the probe
temperature reading. This OID will show a highTempViolation(2)
if the current temperature reading shown in the
'iemStatusProbeCu… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.7 |
| iemStatusProbeLowTempViolation mandatory The high temperature violation status of the probe
temperature reading. This OID will show a lowTempViolation(2)
if the current temperature reading shown in the
'iemStatusProbeCur… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.8 |
| iemStatusProbeHighHumidViolation mandatory The high humidity violation status of the probe humidity
reading. This OID will show a highTempViolation(2)
if the current humidity reading shown in the
'iemStatusProbeCurrentHumi… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.3.2.1.9 |