iemConfigProbeLowHumidThreshold
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.7
Object
column
mandatory
r/w
Integer32
The low humidity alarm threshold for the probe in percent relative humidity.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.10.2.2.2.1.7- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- iemConfigProbesEntry
- Table
- iemConfigProbesTable
- Siblings
- 21
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| iemConfigProbeNumber mandatory The index to a Environmental Monitor probe entry. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.1 |
| iemConfigProbeHighHumidEnable mandatory The high humidity alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enabled(2… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.10 |
| iemConfigProbeLowHumidEnable mandatory The low humidity alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enabled(2)… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.11 |
| iemConfigProbeMaxTempThreshold mandatory The maximun temperature alarm threshold for the probe.
Units are displayed in the scale selected in the
'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.12 |
| iemConfigProbeMinTempThreshold mandatory The minimun temperature alarm threshold for the probe.
Units are displayed in the scale selected in the
'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.13 |
| iemConfigProbeMaxHumidThreshold mandatory The maximum humidity alarm threshold for the probe in
percent relative humidity. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.14 |
| iemConfigProbeMinHumidThreshold mandatory The minimum humidity alarm threshold for the probe in
percent relative humidity. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.15 |
| iemConfigProbeMaxTempEnable mandatory The maximum temperature alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to ena… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.16 |
| iemConfigProbeMinTempEnable mandatory The low temperature alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enabled… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.17 |
| iemConfigProbeMaxHumidEnable mandatory The maximum humidity alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enable… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.18 |
| iemConfigProbeMinHumidEnable mandatory The minimum humidity alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enable… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.19 |
| iemConfigProbeName mandatory A descriptive name for the probe set by the user,
possibly denoting its location or purpose. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.2 |
| iemConfigProbeTempHysteresis mandatory The number of degrees beyond the temperature thresholds
at which an active temperature alarm will be cleared.
This configuration setting applies to all temperature
thresholds.
Uni… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.20 |
| iemConfigProbeHumidHysteresis mandatory The number of percent RH points beyond the humidity
thresholds at which an active humidity alarm will be
cleared. This configuration setting applies to all
humidity thresholds.
Un… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.21 |
| iemConfigProbeLocation mandatory A string describing the location of the probe. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.22 |
| iemConfigProbeHighTempThreshold mandatory The high temperature alarm threshold for the probe.
Units are displayed in the scale selected in the
'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.3 |
| iemConfigProbeLowTempThreshold mandatory The low temperature alarm threshold for the probe.
Units are displayed in the scale selected in the
'iemConfigProbeTempUnits' OID (Celsius or Fahrenheit). | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.4 |
| iemConfigProbeTempUnits mandatory The temperature scale used to display the temperature
thresholds of the probe, Celsius(1) or Fahrenheit(2).
This setting is based on the system preferences
configuration in the ag… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.5 |
| iemConfigProbeHighHumidThreshold mandatory The high humidity alarm threshold for the probe in
percent relative humidity. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.6 |
| iemConfigProbeHighTempEnable mandatory The high temperature alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enable… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.8 |
| iemConfigProbeLowTempEnable mandatory The low temperature alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enabled… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.2.2.2.1.9 |