emsProbeStatusProbeSerialNumber
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.9
Object
A label indicating the type (Local[L] or Remote[R]) and Number of the probe. For example, the first local probe would be L1 and the third remote probe would be R3.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.10.3.13.1.1.9- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- emsProbeStatusEntry
- Table
- emsProbeStatusTable
- Siblings
- 17
Syntax
RFC1213-MIBDisplayString
- Source
- RFC1213-MIBDisplayString
- Base type
OctetString
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| emsProbeStatusProbeIndex mandatory The index to the probe entry. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.1 |
| emsProbeStatusProbeCommStatus mandatory The state of communications to the probe.
commNeverDiscovered(1) indicates there has never been communications with this device.
commsEstablished(2) indicates communication is nor… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.10 |
| emsProbeStatusProbeAlarmStatus mandatory The alarm status of the probe. This integer should be interpreted
as a bit map, with each bit representing the presence or absence of
the specific alarm conditions listed below. … | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.11 |
| emsProbeStatusProbeMaxTempThresh mandatory Probe maximum temperature threshold.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsiu… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.12 |
| emsProbeStatusProbeMinTempThresh mandatory Probe minimum temperature threshold.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsiu… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.13 |
| emsProbeStatusProbeMaxHumidityThresh mandatory Probe maximum humidity threshold.
Values are represented in whole number percentage. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.14 |
| emsProbeStatusProbeMinHumidityThresh mandatory Probe minimum humidity threshold.
Values are represented in whole number percentage. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.15 |
| emsProbeStatusProbeVoltage mandatory Probe voltage reading.
Values are displayed in tenths of Volts DC. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.16 |
| emsProbeStatusProbeMaxVoltThresh mandatory Probe maximum voltage threshold in Volts. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.17 |
| emsProbeStatusProbeMinVoltThresh mandatory Probe minimum voltage threshold in Volts. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.18 |
| emsProbeStatusProbeName mandatory The name of the probe. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.2 |
| emsProbeStatusProbeTemperature mandatory Probe temperature reading.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsius or Fahre… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.3 |
| emsProbeStatusProbeHighTempThresh mandatory Probe high temperature threshold.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsius o… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.4 |
| emsProbeStatusProbeLowTempThresh mandatory Probe low temperature threshold.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsius or… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.5 |
| emsProbeStatusProbeHumidity mandatory Probe humidity reading.
Values are represented in whole number percentage. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.6 |
| emsProbeStatusProbeHighHumidityThresh mandatory Probe high humidity threshold.
Values are represented in whole number percentage. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.7 |
| emsProbeStatusProbeLowHumidityThresh mandatory Probe low humidity threshold.
Values are represented in whole number percentage. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.13.1.1.8 |