emsProbeConfigProbeLTDecTempVariance
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.19
Object
column
mandatory
r/w
Integer32
Probe long-term decreasing temperature variance used for rate of change alarms.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsius or Fahrenheit).
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.10.3.7.1.1.19- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- emsProbeConfigEntry
- Table
- emsProbeConfigTable
- Siblings
- 21
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| emsProbeConfigProbeIndex mandatory The index to the probe entry. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.1 |
| emsProbeConfigProbeMaxHumidityThresh mandatory Probe maximum humidity threshold.
Values are represented in whole number percentage. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.10 |
| emsProbeConfigProbeMinHumidityThresh mandatory Probe minimum humidity threshold.
Values are represented in whole number percentage. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.11 |
| emsProbeConfigProbeDeltaHumidity mandatory Probe delta humidity.
Values are represented in whole number percentage. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.12 |
| emsProbeConfigProbeSTIncTempVariance mandatory Probe short-term increasing temperature variance used for rate of change alarms.
Values are represented in whole number degrees.
Units are displayed in the scale sh… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.13 |
| emsProbeConfigProbeSTIncTempTime mandatory Probe short-term increasing temperature time used for rate of change alarms.
Values are represented in whole number minutes. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.14 |
| emsProbeConfigProbeSTDecTempVariance mandatory Probe short-term decreasing temperature variance used for rate of change alarms.
Values are represented in whole number degrees.
Units are displayed in the scale sh… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.15 |
| emsProbeConfigProbeSTDecTempTime mandatory Probe short-term decreasing temperature time used for rate of change alarms.
Values are represented in whole number minutes. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.16 |
| emsProbeConfigProbeLTIncTempVariance mandatory Probe long-term increasing temperature variance used for rate of change alarms.
Values are represented in whole number degrees.
Units are displayed in the scale sho… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.17 |
| emsProbeConfigProbeLTIncTempTime mandatory Probe long-term increasing temperature time used for rate of change alarms.
Values are represented in whole number hours. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.18 |
| emsProbeConfigProbeName mandatory The name of the probe. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.2 |
| emsProbeConfigProbeLTDecTempTime mandatory Probe long-term decreasing temperature time used for rate of change alarms.
Values are represented in whole number hours. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.20 |
| emsProbeConfigProbeMaxVoltThresh mandatory Probe maximum voltage threshold in tenths of Volts. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.21 |
| emsProbeConfigProbeMinVoltThresh mandatory Probe minimum voltage threshold in tenths of Volts. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.22 |
| emsProbeConfigProbeHighTempThresh mandatory Probe high temperature threshold.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsius o… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.3 |
| emsProbeConfigProbeLowTempThresh mandatory Probe low temperature threshold.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsius or… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.4 |
| emsProbeConfigProbeHighHumidityThresh mandatory Probe high humidity threshold.
Values are represented in whole number percentage. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.5 |
| emsProbeConfigProbeLowHumidityThresh mandatory Probe low humidity threshold.
Values are represented in whole number percentage. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.6 |
| emsProbeConfigProbeMaxTempThresh mandatory Probe maximum temperature threshold.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsiu… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.7 |
| emsProbeConfigProbeMinTempThresh mandatory Probe minimum temperature threshold.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsiu… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.8 |
| emsProbeConfigProbeDeltaTemp mandatory Probe delta temperature.
Values are represented in whole number degrees.
Units are displayed in the scale shown in
the emsStatusSysTempUnits OID (Celsius or Fahrenh… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.3.7.1.1.9 |