emStatusProbeNumber
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.1
Object
column
mandatory
Integer32
The index of the probe.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.10.1.3.3.1.1- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- emStatusProbesEntry
- Table
- emStatusProbesTable
- Siblings
- 13
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| emStatusProbeLowHumidViolation mandatory The low humidity violation status of the probe humidity
reading. This OID will show a lowTempViolation(2)
if the current humidity reading shown in the
'emStatusProbeCurrentHumid' … | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.10 |
| emStatusProbeMaxTempViolation mandatory The max temperature violation status of the probe
temperature reading. This OID will show a maxTempViolation(2)
if the current temperature reading shown in the
'emStatusProbeCurre… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.11 |
| emStatusProbeMinTempViolation mandatory The minimum temperature violation status of the probe
temperature reading. This OID will show a minTempViolation(2)
if the current temperature reading shown in the
'emStatusProbeC… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.12 |
| emStatusProbeMaxHumidViolation mandatory The maximum humidity violation status of the probe humidity
reading. This OID will show a maxTempViolation(2)
if the current humidity reading shown in the
'emStatusProbeCurrentHum… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.13 |
| emStatusProbeMinHumidViolation mandatory The minimum humidity violation status of the probe humidity
reading. This OID will show a minTempViolation(2)
if the current humidity reading shown in the
'emStatusProbeCurrentHum… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.14 |
| emStatusProbeName mandatory A descriptive name for the probe set by the user,
possibly denoting its location or purpose. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.2 |
| emStatusProbeStatus mandatory The connected status of the probe, either
disconnected(1) or connected(2). | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.3 |
| emStatusProbeCurrentTemp mandatory The current temperature reading from the probe displayed
in the units shown in the 'emStatusProbeTempUnits' OID
(Celsius or Fahrenheit). | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.4 |
| emStatusProbeTempUnits mandatory The temperature scale used to display the temperature
thresholds of the probe, Celsius(1) or Fahrenheit(2).
This setting is based on the system preferences
configuration in the ag… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.5 |
| emStatusProbeCurrentHumid mandatory The current humidity reading from the probe in
percent relative humidity. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.6 |
| emStatusProbeHighTempViolation mandatory The high temperature violation status of the probe
temperature reading. This OID will show a highTempViolation(2)
if the current temperature reading shown in the
'emStatusProbeCur… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.7 |
| emStatusProbeLowTempViolation mandatory The high temperature violation status of the probe
temperature reading. This OID will show a lowTempViolation(2)
if the current temperature reading shown in the
'emStatusProbeCurr… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.8 |
| emStatusProbeHighHumidViolation mandatory The high humidity violation status of the probe humidity
reading. This OID will show a highTempViolation(2)
if the current humidity reading shown in the
'emStatusProbeCurrentHumid… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.3.3.1.9 |