emConfigProbeMinTempEnable
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.17
Object
column
mandatory
r/w
Enumeration
The minimum temperature alarm enable/disable for the probe. No alarm will be generated if this value is set to disabled(1). The alarm will be generated if this value is set to enabled(2) and the threshold has been violated.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.10.1.2.2.1.17- Type
- column
- Access
- readwrite
- Status
- mandatory
- Parent
- emConfigProbesEntry
- Table
- emConfigProbesTable
- Siblings
- 21
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | disabled |
2 | enabled |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| emConfigProbeNumber mandatory The index into an Environmental Monitor probe entry. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.1 |
| emConfigProbeHighHumidEnable mandatory The high humidity alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enabled(2… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.10 |
| emConfigProbeLowHumidEnable mandatory The low humidity alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enabled(2)… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.11 |
| emConfigProbeMaxTempThreshold mandatory The maximum temperature alarm threshold for the probe.
Units are displayed in the scale selected in
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.12 |
| emConfigProbeMinTempThreshold mandatory The minimum temperature alarm threshold for the probe.
Units are displayed in the scale selected in
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.13 |
| emConfigProbeMaxHumidThreshold mandatory The maximun humidity alarm threshold for the probe in
percent relative humidity. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.14 |
| emConfigProbeMinHumidThreshold mandatory The minimum humidity alarm threshold for the probe in
percent relative humidity. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.15 |
| emConfigProbeMaxTempEnable mandatory The maximum temperature alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to ena… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.16 |
| emConfigProbeMaxHumidEnable mandatory The maximum humidity alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enable… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.18 |
| emConfigProbeMinHumidEnable mandatory The minimum humidity alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enable… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.19 |
| emConfigProbeName mandatory A descriptive name of the probe set by the user,
possibly denoting its location or purpose. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.2 |
| emConfigProbeTempHysteresis mandatory The number of degrees beyond the temperature thresholds
at which an active temperature alarm will be cleared.
This configuration setting applies to all temperature
thresholds.
Uni… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.20 |
| emConfigProbeHumidHysteresis mandatory The number of percent RH points beyond the humidity
thresholds at which an active humidity alarm will be
cleared. This configuration setting applies to all
humidity thresholds.
Un… | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.21 |
| emConfigProbeLocation mandatory A string describing the location of the probe. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.22 |
| emConfigProbeHighTempThreshold mandatory The high temperature alarm threshold for the probe.
Units are displayed in the scale selected in
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.3 |
| emConfigProbeLowTempThreshold mandatory The low temperature alarm threshold for the probe.
Units are displayed in the scale selected in
the 'emConfigProbeTempUnits' OID (Celsius or Fahrenheit). | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.4 |
| emConfigProbeTempUnits mandatory The temperature scale used to display the temperature
thresholds of the probe, Celsius(1) or Fahrenheit(2).
This setting is based on the system preferences
configuration in the ag… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.5 |
| emConfigProbeHighHumidThreshold mandatory The high humidity alarm threshold for the probe in
percent relative humidity. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.6 |
| emConfigProbeLowHumidThreshold mandatory The low humidity alarm threshold for the probe in
percent relative humidity. | column | Integer32 | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.7 |
| emConfigProbeHighTempEnable mandatory The high temperature alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enable… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.8 |
| emConfigProbeLowTempEnable mandatory The low temperature alarm enable/disable for the
probe. No alarm will be generated if this value
is set to disabled(1). The alarm will be
generated if this value is set to enabled… | column | Enumeration | .1.3.6.1.4.1.318.1.1.10.1.2.2.1.9 |