battManString2BatteryDryout
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.16.10.4.1.9
Object
column
mandatory
Enumeration
When set to alarm(2), indicates a battery has a dryout condition.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.16.10.4.1.9- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- battManString2BatteryEntry
- Table
- battManString2BatteryTable
- Siblings
- 13
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | normal |
2 | alarm |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| battManString2BatteryIndex mandatory Index of string entries in the table. | column | Integer32 | .1.3.6.1.4.1.318.1.1.16.10.4.1.1 |
| battManString2BatteryUserHighVoltageAlarm mandatory When set to alarm(2), indicates a battery has violated
the user level high voltage limit. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.4.1.10 |
| battManString2BatteryUserLowVoltageAlarm mandatory When set to alarm(2), indicates a battery has violated
the user level low voltage limit. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.4.1.11 |
| battManString2BatteryChemHighVoltageAlarm mandatory When set to alarm(2), indicates a battery has violated
the chemistry level high voltage limit. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.4.1.12 |
| battManString2BatteryChemLowVoltageAlarm mandatory When set to alarm(2), indicates a battery has violated
the chemistry level low voltage limit. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.4.1.13 |
| battManString2BatteryOpenCell mandatory When set to alarm(2), indicates the battery has an open
cell or an inter-connection is abnormal. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.4.1.14 |
| battManString2BatteryVoltage mandatory The battery voltage in millivolts DC. | column | Integer32 | .1.3.6.1.4.1.318.1.1.16.10.4.1.2 |
| battManString2BatteryLowestVoltage mandatory The lowest battery discharge voltage during the last power event in millivolts DC. | column | Integer32 | .1.3.6.1.4.1.318.1.1.16.10.4.1.3 |
| battManString2BatteryCellShorted mandatory When set to alarm(2), indicates that a battery cell is shorted. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.4.1.4 |
| battManString2BatteryOpenFuseOrConnection mandatory When set to alarm(2), indicates that a fuse or connection is open. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.4.1.5 |
| battManString2BatteryLowCapacity mandatory When set to alarm(2), indicates a battery has low capacity. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.4.1.6 |
| battManString2BatteryHighOhmicValue mandatory When set to alarm(2), indicates a battery has a high ohmic value. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.4.1.7 |
| battManString2BatteryThermalRunaway mandatory When set to alarm(2), indicates a battery has a thermal runaway condition. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.4.1.8 |