battManString1BatteryIndex
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.16.10.2.1.1
Object
column
mandatory
Integer32
Index of string entries in the table.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.16.10.2.1.1- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- battManString1BatteryEntry
- Table
- battManString1BatteryTable
- Siblings
- 13
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| battManString1BatteryUserHighVoltageAlarm mandatory When set to alarm(2), indicates a battery has violated
the user level high voltage limit. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.10 |
| battManString1BatteryUserLowVoltageAlarm mandatory When set to alarm(2), indicates a battery has violated
the user level low voltage limit. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.11 |
| battManString1BatteryChemHighVoltageAlarm mandatory When set to alarm(2), indicates a battery has violated
the chemistry level high voltage limit. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.12 |
| battManString1BatteryChemLowVoltageAlarm mandatory When set to alarm(2), indicates a battery has violated
the chemistry level low voltage limit. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.13 |
| battManString1BatteryOpenCell mandatory When set to alarm(2), indicates the battery has an open
cell or an inter-connection is abnormal. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.14 |
| battManString1BatteryVoltage mandatory The battery voltage in millivolts DC. | column | Integer32 | .1.3.6.1.4.1.318.1.1.16.10.2.1.2 |
| battManString1BatteryLowestVoltage mandatory The lowest battery discharge voltage during the last power event in millivolts DC. | column | Integer32 | .1.3.6.1.4.1.318.1.1.16.10.2.1.3 |
| battManString1BatteryCellShorted mandatory When set to alarm(2), indicates that a battery cell is shorted. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.4 |
| battManString1BatteryOpenFuseOrConnection mandatory When set to alarm(2), indicates that a fuse or connection is open. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.5 |
| battManString1BatteryLowCapacity mandatory When set to alarm(2), indicates a battery has low capacity. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.6 |
| battManString1BatteryHighOhmicValue mandatory When set to alarm(2), indicates a battery has a high ohmic value. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.7 |
| battManString1BatteryThermalRunaway mandatory When set to alarm(2), indicates a battery has a thermal runaway condition. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.8 |
| battManString1BatteryDryout mandatory When set to alarm(2), indicates a battery has a dryout condition. | column | Enumeration | .1.3.6.1.4.1.318.1.1.16.10.2.1.9 |