battManConfig
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.16.6
Object
node
No description available.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.16.6- Type
- node
- Parent
- battMan
- Siblings
- 13
- Children
- 22
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| battManIdent | node | - | .1.3.6.1.4.1.318.1.1.16.1 |
| battManBatteryStatus | node | - | .1.3.6.1.4.1.318.1.1.16.10 |
| battManInputContactStatus | node | - | .1.3.6.1.4.1.318.1.1.16.11 |
| battManControl | node | - | .1.3.6.1.4.1.318.1.1.16.12 |
| battManTestResults | node | - | .1.3.6.1.4.1.318.1.1.16.13 |
| battManUnitStatus | node | - | .1.3.6.1.4.1.318.1.1.16.14 |
| battManSystemCalib | node | - | .1.3.6.1.4.1.318.1.1.16.2 |
| battManUnitCalib | node | - | .1.3.6.1.4.1.318.1.1.16.3 |
| battManStringCalib | node | - | .1.3.6.1.4.1.318.1.1.16.4 |
| battManBatteryCalib | node | - | .1.3.6.1.4.1.318.1.1.16.5 |
| battManAlarm | node | - | .1.3.6.1.4.1.318.1.1.16.7 |
| battManSystemStatus | node | - | .1.3.6.1.4.1.318.1.1.16.8 |
| battManStringStatus | node | - | .1.3.6.1.4.1.318.1.1.16.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| battManConfigApplication obsolete This OID has been deprecated. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.16.6.1 |
| battManConfigMaxPilotTempC mandatory The maximum pilot battery temperature alarm limit in tenths of degrees Celsius. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.10 |
| battManConfigMaxAmbientTempF mandatory The maximum ambient temperature alarm limit in tenths of degrees Fahrenheit. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.11 |
| battManConfigMaxAmbientTempC mandatory The maximum ambient temperature alarm limit in tenths of degrees Celsius. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.12 |
| battManConfigMinAmbientTempF mandatory The Minimum Ambient Temperature alarm limit in tenths of degrees Fahrenheit. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.13 |
| battManConfigMinAmbientTempC mandatory The Minimum Ambient Temperature alarm limit in tenths of degrees Celsius. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.14 |
| battManConfigMaxRippleCurrent mandatory The maximum ripple current alarm limit for the monitored battery
strings in percent of AH capacity. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.15 |
| battManConfigMaxCurrentAcceptanceDeviation mandatory The maximum current acceptance deviation alarm limit in percent. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.16 |
| battManConfigMonitorWireLength mandatory The monitor wire length:
fiftyFeetOrLess (1) indicates that the wire length is less than or equal to 50 feet.
moreThanFiftyFeet (2) indicates that the wire length is greater than … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.16.6.17 |
| battManConfigDischargeVoltageAlarmLevel mandatory The discharge voltage alarm level in percent. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.18 |
| battManConfigAutoAnnunciatorReset mandatory The annunciator output signal reset method:
disabled(1) means the annunciator signal output will be reset when the reset button is pressed.
enabled(2) means the annunciator will s… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.16.6.19 |
| battManConfigBatteryChemistry mandatory The battery chemistry of the monitored batteries:
LeadAcid(1) Lead Acid or
Nickel-Cadmium(2) Nickel-Cadmium. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.16.6.2 |
| battManConfigSuspendCellVoltage mandatory This is used along with the number of cells per battery
and the number of batteries per string to determine if
a battery string has violated the low voltage limit. If
so, the Batt… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.20 |
| battManConfigOhmicTestWaitTime mandatory The amount of time in seconds after a discharge event before
data will be collected for the ohmic value calculation. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.21 |
| battManConfigNumberOfBoosts mandatory The number of consecutive times the Battery Management
System applies a charge to each battery during a boost
cycle. Batteries with a Rated Battery AH Capacity
less than or equal… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.22 |
| battManConfigBatteryAHCapacity mandatory The amp hour capacity of the monitored batteries 5-4000 AH. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.3 |
| battManConfigNumberofStrings mandatory The number of strings in the battery manager system. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.4 |
| battManConfigBatteriesperString mandatory The number of batteries per string. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.5 |
| battManConfigCellsperBattery mandatory The number of cells per battery (1, 2, 4 or 6 for lead-acid, 1 or 2 for NiCd. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.16.6.6 |
| battManConfigMinCellVoltage mandatory The minimum battery cell voltage alarm limit in millivolts DC. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.7 |
| battManConfigMaxCellVoltage mandatory The maximum battery cell voltage alarm limit in millivolts DC. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.8 |
| battManConfigMaxPilotTempF mandatory The maximum pilot battery temperature alarm limit in tenths of degrees Fahrenheit. | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.16.6.9 |