ats5gSwitchSourceBFrequency
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.33.3.1.25
Object
column
mandatory
Integer32
This is the measured line frequency of source B reported in Hertz (Hz).
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.33.3.1.25- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- ats5gDeviceSwitchEntry
- Table
- ats5gDeviceSwitchTable
- Siblings
- 40
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ats5gSwitchDeviceIndex mandatory This value is the data entry's index in the switching table. | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.1 |
| ats5gSwitchSourceAStatus mandatory This is the input status of source A. The ATS will use source B as the selected source
while this value is fail(1). | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.10 |
| ats5gSwitchSourceBStatus mandatory This is the input status of source B. The ATS will use source A as the selected source
while this value is fail(1). | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.11 |
| ats5gSwitchRatedVoltage mandatory This is the default nominal line VRMS in volts (V) for this unit. | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.12 |
| ats5gSwitchConfigNominalVoltage mandatory This is the configurable line VRMS in volts (V) that will be used to select sources. | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.13 |
| ats5gSwitchConfigTransferVoltageRange mandatory This value specifies which voltage transfer range should be used to disqualify
sources and raise alarms. The narrow transfer voltage must be less than the medium
transfer voltage,… | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.14 |
| ats5gSwitchConfigTransferVoltageWide mandatory This is the configurable transfer range in volts (V) used to disqualify sources when
ats5gSwitchConfigTransferVoltageRange is wide(1). | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.15 |
| ats5gSwitchConfigTransferVoltageMedium mandatory This is the configurable transfer range in volts (V) used to disqualify sources when
ats5gSwitchConfigTransferVoltageRange is medium(2). | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.16 |
| ats5gSwitchConfigTransferVoltageNarrow mandatory This is the configurable transfer range in volts (V) used to disqualify sources when
ats5gSwitchConfigTransferVoltageRange is narrow(3). | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.17 |
| ats5gSwitchConfigVoltageSensitivity mandatory This is the configured sensitivity threshold for rapid changes to input voltage.
It is recommended to use high(1) unless frequent small changes are expected. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.18 |
| ats5gSwitchSourceAVoltage mandatory This is the measured line VRMS of source A reported in volts (V). | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.19 |
| ats5gSwitchModuleID mandatory This value is the ats5gIdentConfigModuleID of the device being queried. | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.2 |
| ats5gSwitchSourceBVoltage mandatory This is the measured line VRMS of source B reported in volts (V). | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.20 |
| ats5gSwitchRatedFrequency mandatory This is the default nominal line frequency for this unit reported in Hertz (Hz). | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.21 |
| ats5gSwitchConfigNominalFrequency mandatory This is the configurable line frequency in Hertz (Hz) that will be used to select
sources. If the difference between ats5gSwitchConfigNominalFrequency and a source's
measured freq… | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.22 |
| ats5gSwitchConfigFrequencyDeviation mandatory This is the configurable frequency deviation in Hertz (Hz) that will be used to select
sources. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.23 |
| ats5gSwitchSourceAFrequency mandatory This is the measured line frequency of source A reported in Hertz (Hz). | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.24 |
| ats5gSwitchEventCountStartTime mandatory This value is the time and date of the last event count reset action. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.33.3.1.26 |
| ats5gSwitchEventCountRedundancyLoss mandatory This value tracks the number of redundancy loss events. It increments each time
a source becomes invalid. | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.27 |
| ats5gSwitchEventCountSourceSwitch mandatory This value tracks the number of source switch events. It increments each time the
selected source changes. | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.28 |
| ats5gSwitchEventCountSourcePrefChange mandatory This value tracks the number of preferred source configuration change events.
It increments each time the user updates their source preference. | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.29 |
| ats5gSwitchOrientation mandatory This value describes the voltage orientation of the ATS. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.3 |
| ats5gSwitchEventCountSpikeOrDrop mandatory This value tracks voltage spike and drop events. It increments each time a
source's measured instantaneous voltage increases or decreases rapidly.
This depends on configured volta… | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.30 |
| ats5gSwitchEventCountSurgeOrDroop mandatory This value tracks voltage surge or droop events. It increments each time a
source's calculated VRMS increases or decreases rapidly.
This does not depend on any user configurations. | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.31 |
| ats5gSwitchEventCountFreqOutOfRange mandatory This value tracks frequency threshold violations. It increments each time a source
is disqualified because the difference between its measured frequency and the
configured nominal… | column | Integer32 | .1.3.6.1.4.1.318.1.1.33.3.1.32 |
| ats5gSwitchControlEventCountReset mandatory This control resets the event counts when the value is set to reset(2). | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.33 |
| ats5gSwitchVoltageOutStatus mandatory This value is on(2) while the output outlets are powered. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.34 |
| ats5gSwitchOverCurrentState mandatory This value is atsOverCurrent(1) when the ATS has exceeded the output
current threshold and will not allow a switch over to the alternate power
source if the current source fails. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.35 |
| ats5gSwitchPhaseSyncStatus mandatory This value tracks the phase sync status. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.36 |
| ats5gSwitchSourceA24VSupplyStatus mandatory This value tracks the internal source A 24VDC power supply status. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.37 |
| ats5gSwitchSourceB24VSupplyStatus mandatory This value tracks the internal source B 24VDC power supply status. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.38 |
| ats5gSwitchSourceA48VSupplyStatus mandatory This value tracks the internal source A 48VDC power supply status. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.39 |
| ats5gSwitchCumulativeAlarmStatus mandatory This is the severity of the most severe alarm currently active. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.4 |
| ats5gSwitchSourceB48VSupplyStatus mandatory This value tracks the internal source B 48VDC power supply status. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.40 |
| ats5gSwitch3p3VSupplyStatus mandatory This value tracks the internal 3.3VDC power supply status. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.41 |
| ats5gSwitchCommunicationStatus mandatory This is the communication status between the network management card
and the automatic transfer switch. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.5 |
| ats5gSwitchConfigFrontPanelLockout mandatory This is the configurable lockout status of the source preference toggle button
on the front panel. The button does nothing while the front panel is locked. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.6 |
| ats5gSwitchConfigPreferredSource mandatory This is the configurable source preference. If the ATS is fully redundant the
preferred source will be the selected source. If the preferred source is none(3),
the ATS will switch… | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.7 |
| ats5gSwitchSelectedSource mandatory This is the selected source that will be used to power downstream devices. | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.8 |
| ats5gSwitchRedundancyState mandatory This is the ATS redundancy status. While this value is atsFullyRedundant(2),
either input may be used to power downstream devices. While this value is
atsRedundancyLost(1), one in… | column | Enumeration | .1.3.6.1.4.1.318.1.1.33.3.1.9 |