airIRRP100UnitConfigStartupDelay
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.1
Object
scalar
mandatory
r/w
Integer32
The startup delay in seconds.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.1- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- airIRRP100UnitConfig
- Siblings
- 14
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airIRRP100UnitConfigReheatEnable mandatory Enable/disable reheat. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.10 |
| airIRRP100UnitConfigHeatAssistEnable mandatory Enable/disable heat assist. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.11 |
| airIRRP100UnitConfigPowerSourceConfig mandatory Configure the input power source: (1) single feed or (2) dual feed. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.12 |
| airIRRP100UnitConfigUnitRoleOverride mandatory When this OID value is (1) automatic, the system determines
which units are used as primary units and which units are used as backups.
When this OID value is (2) forcedOn, the con… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.13 |
| airIRRP100UnitConfigSecondaryPowerFeedCapability mandatory Available on chilled water units. When the power source config setting
is set to dual, setting this value to reduced (2) will inhibit the heater
and humdifier when the unit is be… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.14 |
| airIRRP100UnitConfigIdleOnCoolFail mandatory When this OID value is (1) enable, the unit idles if it detects that it is blowing warm
air into the cold aisle. The unit will attempt to restart at 5 minute intervals. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.15 |
| airIRRP100UnitConfigCoolCapacity mandatory The cooling capacity options setting. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.2 |
| airIRRP100UnitConfigIdleOnLeakDetect mandatory The idle on leak options setting. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.3 |
| airIRRP100UnitConfigInputNormalState mandatory The normal state of the input contact. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.4 |
| airIRRP100UnitConfigOutputNormalState mandatory The normal state of the output relay. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.5 |
| airIRRP100UnitConfigOutputSource mandatory The source of output relay change. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.6 |
| airIRRP100UnitConfigHumidifyEnable mandatory Enable/disable humidification. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.7 |
| airIRRP100UnitConfigHumidifierControl mandatory The humidifier drain control. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.8 |
| airIRRP100UnitConfigDehumidifyEnable mandatory Enable/disable dehumidification. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.3.3.1.2.6.9 |