airIRG3RDUStatusPowerSource
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.9
Object
column
mandatory
Enumeration
The RDU power source status.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.13.6.4.2.1.9- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- airIRG3RDUStatusEntry
- Table
- airIRG3RDUStatusTable
- Siblings
- 42
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | singleFeed |
2 | dualFeed |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airIRG3RDUStatusDeviceIndex mandatory Index of RDU status table. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.1 |
| airIRG3RDUStatusTotalRDUOutputPower mandatory The RDU output power in tenths of kilowatts (kW). | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.10 |
| airIRG3RDUStatusInletWaterTempUS mandatory The RDU inlet water temperature in tenths of
degrees Fahrenheit. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.11 |
| airIRG3RDUStatusInletWaterTempMetric mandatory The RDU inlet water temperature in tenths of
degrees Celsius. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.12 |
| airIRG3RDUStatusOutletWaterTempUS mandatory The RDU outlet water temperature in tenths of
degrees Fahrenheit. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.13 |
| airIRG3RDUStatusOutletWaterTempMetric mandatory The RDU outlet water temperature in tenths of
degrees Celsius. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.14 |
| airIRG3RDUStatusCondenserSaturationTempUS mandatory The RDU condenser saturation temperature in tenths of
degrees Fahrenheit. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.15 |
| airIRG3RDUStatusCondenserSaturationTempMetric mandatory The RDU condenser saturation temperature in tenths of
degrees Celsius. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.16 |
| airIRG3RDUStatusDewPointTempUS mandatory The RDU dew point temperature in tenths of
degrees Fahrenheit. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.17 |
| airIRG3RDUStatusDewPointTempMetric mandatory The RDU dew point temperature in tenths of
degrees Celsius. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.18 |
| airIRG3RDUStatusPumpOutletTempUS mandatory The RDU pump outlet temperature in tenths of
degrees Fahrenheit. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.19 |
| airIRG3RDUID mandatory The current RDU ID (1 to F).
Configured RDU only shall display ID, else return -1. | column | RFC1213-MIBDisplayString | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.2 |
| airIRG3RDUStatusPumpOutletTempMetric mandatory The RDU pump outlet temperature in tenths of
degrees Celsius. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.20 |
| airIRG3RDUStatusSubcoolerOutletTempUS mandatory The RDU sub cooler outlet temperature in tenths of
degrees Fahrenheit. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.21 |
| airIRG3RDUStatusSubcoolerOutletTempMetric mandatory The RDU sub cooler outlet temperature in tenths of
degrees Celsius. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.22 |
| airIRG3RDUStatusCondenserOutletTempUS mandatory The RDU condenser outlet temperature in tenths of
degrees Fahrenheit. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.23 |
| airIRG3RDUStatusCondenserOutletTempMetric mandatory The RDU condenser outlet temperature in tenths of
degrees Celsius. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.24 |
| airIRG3RDUStatusCondenserInletTempUS mandatory The RDU condenser inlet temperature in tenths of
degrees Fahrenheit. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.25 |
| airIRG3RDUStatusCondenserInletTempMetric mandatory The RDU condenser inlet temperature in tenths of
degrees Celsius. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.26 |
| airIRG3RDUStatusCondenserOutletPressureUS mandatory The RDU condenser outlet pressure in
pounds per square inch (PSI). | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.27 |
| airIRG3RDUStatusCondenserOutletPressureMetric mandatory The RDU condenser outlet pressure in kiloPascals (KPa). | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.28 |
| airIRG3RDUStatusPump1HeadPressureUS mandatory The RDU Pump 1 head pressure in pounds per square inch (PSI). | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.29 |
| airIRG3RDUStatusOnReadyStandby mandatory The RDU current status. | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.3 |
| airIRG3RDUStatusPump1HeadPressureMetric mandatory The RDU Pump 1 head pressure in kiloPascals (KPa). | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.30 |
| airIRG3RDUStatusPump2HeadPressureUS mandatory The RDU Pump 2 head pressure in pounds per square inch (PSI). | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.31 |
| airIRG3RDUStatusPump2HeadPressureMetric mandatory The RDU Pump 2 head pressure in kiloPascals (KPa). | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.32 |
| airIRG3RDUStatusPump1Speed mandatory The RDU Pump 1 speed in revolutions per minute (RPM). | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.33 |
| airIRG3RDUStatusPump2Speed mandatory The RDU Pump 2 speed in revolutions per minute (RPM). | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.34 |
| airIRG3RDUStatusCWValvePosition mandatory The RDU CW Valve position in % open | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.35 |
| airIRG3RDUStatusReceiverLiquidLevel mandatory The RDU receiver liquid level in % Full | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.36 |
| airIRG3RDUStatusDCPowerSupply1Current mandatory The RDU DC Power Supply 1 Current in Amps | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.37 |
| airIRG3RDUStatusDCPowerSupply2Current mandatory The RDU DC Power Supply 2 Current in Amps | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.38 |
| airIRG3RDUStatusTotalDCPowerSupplyCurrent mandatory The RDU Total DC Power Supply Current in Amps | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.39 |
| airIRG3RDUStatusOperatingMode mandatory The RDU actual operating mode. | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.4 |
| airIRG3RDUStatusInputState mandatory The RDU Input state. | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.40 |
| airIRG3RDUStatusOutputState mandatory The RDU Output state | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.41 |
| airIRG3RDUStatusByPassValvePosition mandatory The RDU By Pass Valve position in % open | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.42 |
| airIRG3RDUStatusRefrigerantLeakDetector mandatory The RDU refrigerant leak detector status. | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.43 |
| airIRG3RDUStatusLeadPump mandatory The RDU lead pump. | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.5 |
| airIRG3RDUStatusStartupDelay mandatory The RDU start up delay in seconds. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.6 |
| airIRG3RDUStatusPumpChangeOverInterval mandatory The RDU pump change over interval in days. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.7 |
| airIRG3RDUStatusStopOnLeakDetect mandatory The RDU status of stop on leak detect. | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.6.4.2.1.8 |