airFMSysReheatEssFunction
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.13.1.4.8.2
Object
scalar
mandatory
r/w
Enumeration
Set the priority of the mode for alarms and events with the nonessential stop behavior. Nonessential modes are disabled during nonessential stop alarms and events. A value of notApplicable indicates that this OID does not apply to this device due to its configuration.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.13.1.4.8.2- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- airFMSysReheat
- Siblings
- 9
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | notApplicable |
2 | yes |
3 | no |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFMSysReheatState mandatory Set the mode to enabled or disabled. Disabled modes
will not operate, and you cannot make changes to their
settings while they are disabled.
A value of notApplicable indicates tha… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.8.1 |
| airFMSysReheatPIDDerivativeD mandatory Set the derivative multiplier to counteract overshoot
and droop during changes in the room load. Measured
in %/(C / min).
A value of -2147483648 indicates that this OID does
not … | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.8.10 |
| airFMSysReheatSetpointC mandatory The target value for the selected control sensor air
for this mode. It must be at least 1.0 C below the
cooling setpoint. Measured in tenths of degrees
Celsius.
A value of -21474… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.8.3 |
| airFMSysReheatSetpointF mandatory The target value for the selected control sensor air
for this mode. It must be at least 1.0 C below the
cooling setpoint. Measured in tenths of degrees
Fahrenheit.
A value of -21… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.8.4 |
| airFMSysReheatDeadbandC mandatory The temperature range that controls output when the
selected control sensor temperature is below the
setpoint. At the bottom of this range, the reheat
mode outputs at 100%. The de… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.8.5 |
| airFMSysReheatDeadbandF mandatory The temperature range that controls output when the
selected control sensor temperature is below the
setpoint. At the bottom of this range, the reheat
mode outputs at 100%. The de… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.8.6 |
| airFMSysReheatPIDMethod mandatory Set the multipliers that the PID algorithm will use
to calculate the output. Proportional,
Proportional + Integral, or Proportional + Integral
+ Derivative.
A value of notApplicab… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.8.7 |
| airFMSysReheatPIDGainP mandatory Set the proportional multiplier to correct for
differences between the selected control sensor
actual temperature and the setpoint. Measured in
%/C.
A value of -2147483648 indica… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.8.8 |
| airFMSysReheatPIDResetRateI mandatory Set the integral multiplier to correct for the
proportional offset. Measured in %/(C * min).
A value of -2147483648 indicates that this OID does
not apply to this device due to i… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.8.9 |