airFMSysHumidify
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.13.1.4.6
Object
node
No description available.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.13.1.4.6- Type
- node
- Parent
- airFMSystem
- Siblings
- 11
- Children
- 7
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFMSysStatus | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.1 |
| airFMSysInputs | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.10 |
| airFMSysOutputs | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.11 |
| airFMSysAlarmMap | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.12 |
| airFMSysDemands | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.2 |
| airFMSysSetup | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.3 |
| airFMSysConfig | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.4 |
| airFMSysCooling | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.5 |
| airFMSysDehumidify | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.7 |
| airFMSysReheat | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.8 |
| airFMSysThresholds | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFMSysHumState mandatory Set the mode to enabled or disabled. Disabled modes
will not operate, and you cannot make changes to their
settings while they are disabled.
A value of notApplicable indicates tha… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.6.1 |
| airFMSysHumEssFunction mandatory Set the priority of the mode for alarms and events
with the nonessential stop behavior. Nonessential
modes are disabled during nonessential stop alarms
and events.
A value of notA… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.6.2 |
| airFMSysHumSetpoint mandatory The target value for the selected control sensor air
for this mode. It must be at least 1.0 % RH below
the dehumidification setpoint. Measured in tenths of
percent relative humid… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.6.3 |
| airFMSysHumDeadband mandatory The humidity range that controls output when the
selected control sensor humidity is below the
setpoint. At the top of this range, the
humidification mode outputs at 100%. The dea… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.6.4 |
| airFMSysHumCtrlSetting mandatory Set the method to control the humidity in the room.
The two methods are Relative Humidity (RH) or Dew
Point of the selected control sensor air. The dew
point method helps correct … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.6.5 |
| airFMSysActualHumCtrl mandatory The humidity control method the system is using.
A value of notApplicable indicates that this OID does
not apply to this device due to its configuration. | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.6.6 |
| airFMSysHumSensBand mandatory The percentage of relative humidity below the
setpoint at which the humidifier will output at 100%
of capacity. Measured in percent relative humidity.
A value of -2147483648 indi… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.6.7 |