airFMSysDehumidify
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.13.1.4.7
Object
node
No description available.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.13.1.4.7- Type
- node
- Parent
- airFMSystem
- Siblings
- 11
- Children
- 9
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFMSysStatus | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.1 |
| airFMSysInputs | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.10 |
| airFMSysOutputs | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.11 |
| airFMSysAlarmMap | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.12 |
| airFMSysDemands | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.2 |
| airFMSysSetup | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.3 |
| airFMSysConfig | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.4 |
| airFMSysCooling | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.5 |
| airFMSysHumidify | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.6 |
| airFMSysReheat | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.8 |
| airFMSysThresholds | node | - | .1.3.6.1.4.1.318.1.1.13.1.4.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFMSysDehumState mandatory Set the mode to enabled or disabled. Disabled modes
will not operate, and you cannot make changes to their
settings while they are disabled.
A value of notApplicable indicates tha… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.7.1 |
| airFMSysDehumEssFunction mandatory Set the priority of the mode for alarms and events
with the nonessential stop behavior. Nonessential
modes are disabled during nonessential stop alarms
and events.
A value of notA… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.7.2 |
| airFMSysDehumSetpoint mandatory The target value for the selected control sensor air
for this mode. It must be at least 1.0 % RH above
the humidification setpoint if a humidifier is
installed. Measured in tenth… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.7.3 |
| airFMSysDehumDeadband mandatory The humidity range above the setpoint at which the
dehumidification mode will output at 100%. The
deadband does not apply to PID controlled modes.
Measured in tenths of percent re… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.7.4 |
| airFMSysDehumCapacity mandatory Set the dehumidification mode to use either half of
the cooling coil or the full coil when dehumidifying
the room.
A value of notApplicable indicates that this OID does
not apply … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.7.5 |
| airFMSysDehumPIDMethod mandatory Set the multipliers that the PID algorithm will use
to calculate the output. Proportional,
Proportional + Integral, or Proportional + Integral
+ Derivative.
A value of notApplicab… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.7.6 |
| airFMSysDehumPIDGainP mandatory Set the proportional multiplier to correct for
differences between the selected control sensor
actual humidity and the setpoint. Measured in %/%RH.
A value of -2147483648 indicat… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.7.7 |
| airFMSysDehumPIDResetRateI mandatory Set the integral multiplier to correct for the
proportional offset. Measured in %/(%RH * min).
A value of -2147483648 indicates that this OID does
not apply to this device due to… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.7.8 |
| airFMSysDehumPIDDerivativeD mandatory Set the derivative multiplier to counteract overshoot
and droop during changes in the room humidity.
Measure in %/(%RH / min).
A value of -2147483648 indicates that this OID does
… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.7.9 |