airFMSysCompRotPeriod
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.13.1.4.5.3
Object
scalar
mandatory
r/w
Integer32
Set how often to perform compressor runtime balancing. Measured in hours. A value of -2147483648 indicates that this OID does not apply to this device due to its configuration.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.13.1.4.5.3- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- airFMSysCooling
- Siblings
- 22
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFMSysCompMinOnTime mandatory Set the minimum time the compressor continues to
operate after it is started. The delay protects the
compressor from damage. Caution: Reducing this delay
shortens compressor life.… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.1 |
| airFMSysCoolSetpointC mandatory The target value for the selected control sensor air
for this mode. It must be at least 1.0 C above the
reheat setpoint if a heater is installed. Measured
in tenths of degrees Ce… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.10 |
| airFMSysCoolSetpointF mandatory The target value for the selected control sensor air
for this mode. It must be at least 1.0 C above the
reheat setpoint if a heater is installed. Measured
in tenths of degrees Fa… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.11 |
| airFMSysCoolDeadbandC mandatory The temperature range that controls output when the
selected control sensor temperature is above the
setpoint. At the top of this range, the cool mode
outputs at 100%. The deadban… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.12 |
| airFMSysCoolDeadbandF mandatory The temperature range that controls output when the
selected control sensor temperature is above the
setpoint. At the top of this range, the cool mode
outputs at 100%. The deadban… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.13 |
| airFMSysCoolEconIsolFunction mandatory Set the Economizer Automatic Coolant Isolation valve
to enabled or disabled. This valve anticipates a
cooling demand and opens the coil fluid valve.
A value of notApplicable indic… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.5.14 |
| airFMSysSuctPresCompensation mandatory Set the Suction Pressure Compensation to enabled or
disabled. This function attempts to keep the suction
pressure from exceeding 95 psi.
A value of notApplicable indicates that th… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.5.15 |
| airFMSysCoilFluidActivThreshC mandatory The minimum coolant temperature required to use the
optional MultiCool or Economizer coil. Measured in
tenths of degrees Celsius.
A value of -2147483648 indicates that this OID d… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.16 |
| airFMSysCoilFluidActivThreshF mandatory The minimum coolant temperature required to use the
optional MultiCool or Economizer coil. Measured in
tenths of degrees Fahrenheit.
A value of -2147483648 indicates that this OI… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.17 |
| airFMSysCoilFluidActivDeadbandC mandatory The controller will disengage the MultiCool or
Economizer coil when the coolant temperature reaches
the coil fluid temperature activation threshold plus
the deadband. Measured in… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.18 |
| airFMSysCoilFluidActivDeadbandF mandatory The controller will disengage the MultiCool or
Economizer coil when the coolant temperature reaches
the coil fluid temperature activation threshold plus
the deadband. Measured in… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.19 |
| airFMSysCompMinOffTime mandatory Set the minimum time the compressor will remain off
after it ceases operation. The delay protects the
compressor from damage. Caution: Reducing this delay
shortens compressor life… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.2 |
| airFMSysCoolPIDMethod mandatory Set the multipliers that the PID algorithm will use
to calculate the cool output. Proportional,
Proportional + Integral, or Proportional + Integral
+ Derivative.
A value of notApp… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.5.20 |
| airFMSysCoolPIDGainP mandatory Set the proportional multiplier to correct for
differences between the selected control sensor
actual temperature and the setpoint. Measured in
%/C.
A value of -2147483648 indica… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.21 |
| airFMSysCoolPIDResetRateI mandatory Set the integral multiplier to correct for the
proportional offset. Measured in %/(C * min).
A value of -2147483648 indicates that this OID does
not apply to this device due to i… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.22 |
| airFMSysCoolPIDDerivativeD mandatory Set the derivative multiplier to counteract overshoot
and droop during changes in the room load. Measured
in %/(C / min).
A value of -2147483648 indicates that this OID does
not … | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.23 |
| airFMSysEconIsolVlvOpenDelay mandatory Set the delay between opening the Economizer Isolator
output relay and engaging the compressors. Measured
in seconds.
A value of -2147483648 indicates that this OID does
not appl… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.4 |
| airFMSysEconIsolVlvCloseDelay mandatory Set the delay between disengaging the compressor and
closing the Economizer Isolator output relay.
Measured in seconds.
A value of -2147483648 indicates that this OID does
not app… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.5 |
| airFMSysCndsrFluidVlvCloseDelay mandatory Set the time the condenser valve remains open after
the compressors disengage. Measured in seconds.
A value of -2147483648 indicates that this OID does
not apply to this device d… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.6 |
| airFMSysInterstageDelay mandatory The DX interstage delay allows the first compressor's
cooling to take effect before engaging the second
compressor. This prevents the second compressor from
cycling on and off exc… | scalar | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.4.5.7 |
| airFMSysCoolState mandatory Set the mode to enabled or disabled. Disabled modes
will not operate, and you cannot make changes to
their settings while they are disabled.
A value of notApplicable indicates tha… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.5.8 |
| airFMSysCoolEssFunction mandatory Set the priority of the mode for alarms and events
with the nonessential stop behavior. Nonessential
modes are disabled during nonessential stop alarms
and events.
A value of notA… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.4.5.9 |