airFMModServIntResetModuleIndex
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.1
Object
column
mandatory
Integer32
The index of the module.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.1- Type
- column
- Access
- readonly
- Status
- mandatory
- Parent
- airFMModServIntResetEntry
- Table
- airFMModServIntResetTable
- Siblings
- 8
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFMModServIntComp1Reset mandatory Reset the compressor 1 service interval maintenance
alarm.
Getting this OID will do nothing and return the
noOperation value.
A value of notApplicable indicates that this OID does… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.2 |
| airFMModServIntComp2Reset mandatory Reset the compressor 2 service interval maintenance
alarm.
Getting this OID will do nothing and return the
noOperation value.
A value of notApplicable indicates that this OID does… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.3 |
| airFMModServIntHeaterReset mandatory Reset the heater service interval maintenance alarm.
Getting this OID will do nothing and return the
noOperation value.
A value of notApplicable indicates that this OID does
not a… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.4 |
| airFMModServIntHumReset mandatory Reset the humidifier service interval maintenance
alarm.
Getting this OID will do nothing and return the
noOperation value.
A value of notApplicable indicates that this OID does
n… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.5 |
| airFMModServIntBlwr1Reset mandatory Reset the blower 1 service interval maintenance
alarm.
Getting this OID will do nothing and return the
noOperation value.
A value of notApplicable indicates that this OID does
not… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.6 |
| airFMModServIntBlwr2Reset mandatory Reset the blower 2 service interval maintenance
alarm.
Getting this OID will do nothing and return the
noOperation value.
A value of notApplicable indicates that this OID does
not… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.7 |
| airFMModServIntBlwrCtrl1Reset mandatory Reset the blower controller 1 service interval
maintenance alarm.
Getting this OID will do nothing and return the
noOperation value.
A value of notApplicable indicates that this O… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.8 |
| airFMModServIntBlwrCtrl2Reset mandatory Reset the blower controller 2 service interval
maintenance alarm.
Getting this OID will do nothing and return the
noOperation value.
A value of notApplicable indicates that this O… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.10.2.1.9 |