airFMModPropEntry
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1
Object
row
mandatory
The module to get information from.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.13.1.5.3.2.1- Type
- row
- Status
- mandatory
- Parent
- airFMModPropTable
- Table
- airFMModPropTable
- Children
- 13
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFMModPropModuleIndex mandatory The index of the module. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.1 |
| airFMModCondPump mandatory Indicates the presence of a condensate pump in the
Modules of this System.
A value of notApplicable indicates that this OID
does not apply to this device due to its configuration. | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.10 |
| airFMModFireDetector mandatory Indicates the presence of a fire detector for each
of the Modules in this System.
A value of notApplicable indicates that this OID
does not apply to this device due to its configu… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.11 |
| airFMModSmokeDetector mandatory Indicates the presence of a smoke detector for each
of the Modules in this System.
A value of notApplicable indicates that this OID
does not apply to this device due to its config… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.12 |
| airFMModWaterDetector mandatory Indicates the presence of a water leak detector for
each of the Modules in this System.
A value of notApplicable indicates that this OID
does not apply to this device due to its c… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.13 |
| airFMModOutputCapacity mandatory The cooling capacity (in Kilowatts) of the displayed
Module.
A value of notApplicable indicates that this OID
does not apply to this device due to its configuration. | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.2 |
| airFMModCapacityCtrl mandatory The method used to load and unload the compressors.
Tandem compressor Modules use two stages (one
compressor each). Single compressor Modules use hot
gas bypass.
A value of notApp… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.3 |
| airFMModHeaterType mandatory The type of reheating device installed in this Module.
A value of notApplicable indicates that this OID
does not apply to this device due to its configuration. | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.4 |
| airFMModElectricHeaterType mandatory The type/capacity of the electric heater, if installed.
A value of notApplicable indicates that this OID
does not apply to this device due to its configuration. | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.5 |
| airFMModHumidifierType mandatory The type of equipment installed in the Module to run
the humidification mode.
A value of notApplicable indicates that this OID
does not apply to this device due to its configurati… | column | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.6 |
| airFMModBlwrFreqSetting mandatory Frequency of the blower in tenths of hertz.
A value of -2147483648 indicates that this OID does
not apply to this device due to its configuration. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.7 |
| airFMModNomCoilDiffPresPa mandatory The difference in pressure on either side of the
cooling/dehumidification coils. Measured in Pascals.
A value of -2147483648 indicates that this OID does
not apply to this device… | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.8 |
| airFMModNomCoilDiffPresInWC mandatory The difference in pressure on either side of the
cooling/dehumidification coils. Measured in
hundredths of inches water column.
A value of -2147483648 indicates that this OID doe… | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFMModPropModuleIndex mandatory The index of the module. | column | Integer32 | .1.3.6.1.4.1.318.1.1.13.1.5.3.2.1.1 |