airFMGroupFailoverSysLowEnvHum
PowerNet-MIB ·
.1.3.6.1.4.1.318.1.1.13.1.3.7.1.6
Object
scalar
mandatory
r/w
Enumeration
Enabling this OID will cause the system to enter a failure state if the low environmental humidity alarm is active. Once in the failure state, environmental control ceases for the system, and the blowers enter the Idle Blower Operation mode. A value of notApplicable indicates that this alarm does not apply to this device due to its configuration.
Context
- MIB
- PowerNet-MIB
- OID
.1.3.6.1.4.1.318.1.1.13.1.3.7.1.6- Type
- scalar
- Access
- readwrite
- Status
- mandatory
- Parent
- airFMGroupFailoverSys
- Siblings
- 13
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | notApplicable |
2 | disable |
3 | enable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| airFMGroupFailoverSysAnyMinorAlarm mandatory Enabling this OID will cause the system to enter
a failure state if any minor system alarm is active.
Once in the failure state, environmental control
ceases for the system, and t… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.1 |
| airFMGroupFailoverSysSupplySensorFail mandatory Enabling this OID will cause the system to enter
a failure state if the supply sensor has failed.
Once in the failure state, environmental control
ceases for the system, and the b… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.10 |
| airFMGroupFailoverSysReturnSensorFail mandatory Enabling this OID will cause the system to enter
a failure state if the return sensor has failed.
Once in the failure state, environmental control
ceases for the system, and the b… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.11 |
| airFMGroupFailoverSysPrimarySensorFail mandatory Enabling this OID will cause the system to enter
a failure state if the primary sensor has failed.
Once in the failure state, environmental control
ceases for the system, and the … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.12 |
| airFMGroupFailoverSysSecondarySensorFail mandatory Enabling this OID will cause the system to enter
a failure state if the secondary sensor has failed.
Once in the failure state, environmental control
ceases for the system, and th… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.13 |
| airFMGroupFailoverSysNoSensorsAvailable mandatory Enabling this OID will cause the system to enter
a failure state if no sensors are available.
Once in the failure state, environmental control
ceases for the system, and the blowe… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.14 |
| airFMGroupFailoverSysAnyMajorAlarm mandatory Enabling this OID will cause the system to enter
a failure state if any major system alarm is active.
Once in the failure state, environmental control
ceases for the system, and t… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.2 |
| airFMGroupFailoverSysHighEnvTemp mandatory Enabling this OID will cause the system to enter
a failure state if the high environmental temperature
alarm is active.
Once in the failure state, environmental control
ceases for… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.3 |
| airFMGroupFailoverSysLowEnvTemp mandatory Enabling this OID will cause the system to enter
a failure state if the low environmental temperature
alarm is active.
Once in the failure state, environmental control
ceases for … | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.4 |
| airFMGroupFailoverSysHighEnvHum mandatory Enabling this OID will cause the system to enter
a failure state if the high environmental humidity
alarm is active.
Once in the failure state, environmental control
ceases for th… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.5 |
| airFMGroupFailoverSysFireAlarm mandatory Enabling this OID will cause the system to enter
a failure state if the fire alarm is active.
Once in the failure state, environmental control
ceases for the system, and the blowe… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.7 |
| airFMGroupFailoverSysSmokeAlarm mandatory Enabling this OID will cause the system to enter
a failure state if the smoke alarm is active.
Once in the failure state, environmental control
ceases for the system, and the blow… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.8 |
| airFMGroupFailoverSysCommLost mandatory Enabling this OID will cause the system to enter
a failure state if the system has lost comm.
Once in the failure state, environmental control
ceases for the system, and the blowe… | scalar | Enumeration | .1.3.6.1.4.1.318.1.1.13.1.3.7.1.9 |