swPoESystemStackingCtrlManagementMode

PoE-MIB · .1.3.6.1.4.1.171.12.24.1.11.1.4

Object

column r/w Enumeration
This mode can be either power_limit mode or auto mode.
power_limit: If power supplied to the port exceeds the power limit
specified for it, this port will be shut down.
auto: The system will automatically determine the PD class of the
device connected to the port in the first stage. Normally, the PD
can be classified as class 1, 2, or 3. If the PD can not be classified,
it will be classified as class 0. For class 0, it will assume that the PD
may consume the max power allowed. At the power feeding stage, if the power
supplied to the port exceeds the upper limit of the detected PD class, this
port will be shut down. For the upper limit for each class, it is 4W for
class 1 PD class, 7W for class 2, and 15.4W for class 3 PD and class 0 PD.

Context

MIB
PoE-MIB
OID
.1.3.6.1.4.1.171.12.24.1.11.1.4
Type
column
Access
readwrite
Status
current
Parent
swPoESystemStackingCtrlEntry
Table
swPoESystemStackingCtrlTable
Siblings
5

Syntax

Enumeration

Values & Constraints

Enumerated Values
1power-limit
2auto

Related Objects

Sibling Objects