swPoESystemPowerDisconnectMethod
PoE-MIB ·
.1.3.6.1.4.1.171.12.24.1.2
Object
scalar
r/w
Enumeration
The power management disconnection method. When the total consumed power exceeds the power budget, the PoE controller initiates port disconnection, to prevent overloading the power supply. The controller uses one of the following two ways to implement the disconnection. deny_next_port: after the power budget has been exceeded, the next port attempting to power up is denied, regardless of its priority. deny_low_priority_port: after the power budget has been exceeded, the next port attempting to power up causes the port with the lowest priority to shut down to allow high-priority ports to power up. The default setting is deny_next_port.
Context
- MIB
- PoE-MIB
- OID
.1.3.6.1.4.1.171.12.24.1.2- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- swPoESystemCtrl
- Siblings
- 5
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | denyNextPort |
2 | denyLowPriorityPort |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| swPoESystemPowerLimit The power budget (in watts) of the PoE sytem. | scalar | Integer32 | .1.3.6.1.4.1.171.12.24.1.1 |
| swPoESystemStackingCtrlTable A table that is used to configure PoE system information based on Unit ID.
The Unit ID is used for stacking. | table | - | .1.3.6.1.4.1.171.12.24.1.11 |
| swPoESystemManagementMode This mode can be either power_limit mode or auto mode.
power_limit: If power supplied to the port exceeds the power limit
specified for it, this port will be shut down.
auto: The… | scalar | Enumeration | .1.3.6.1.4.1.171.12.24.1.3 |
| swPoESystemLedMode Specifies if the system mode will be POE or NORMAL. | scalar | Enumeration | .1.3.6.1.4.1.171.12.24.1.4 |
| swPoESystemCtrlLegacyPD The legacy PD detection state. Enables or disables legacy PD detection on all PoE port. | scalar | Enumeration | .1.3.6.1.4.1.171.12.24.1.6 |