swPoESystemManagementMode
PoE-MIB ·
.1.3.6.1.4.1.171.12.24.1.3
Object
scalar
r/w
Enumeration
This mode can be either power_limit mode or auto mode. power_limit: If power supplied to the port exceeds the power limit specified for it, this port will be shut down. auto: The system will automatically determine the PD class of the device connected to the port in the first stage. Normally, the PD can be classified as class 1, 2, or 3. If the PD cannot be classified, it will be classified as class 0. For class 0, it will assume that the PD may consume the max power allowed. During the power feeding stage, if the power supplied to the port exceeds the upper limit of the detected PD class, this port will be shut down. For the upper limit for each class, it is 4W for class 1 PD class, 7W for class 2, and 15.4W for class 3 PD and class 0 PD.
Context
- MIB
- PoE-MIB
- OID
.1.3.6.1.4.1.171.12.24.1.3- Type
- scalar
- Access
- readwrite
- Status
- current
- Parent
- swPoESystemCtrl
- Siblings
- 5
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | power-limit |
2 | auto |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| swPoESystemPowerLimit The power budget (in watts) of the PoE sytem. | scalar | Integer32 | .1.3.6.1.4.1.171.12.24.1.1 |
| swPoESystemStackingCtrlTable A table that is used to configure PoE system information based on Unit ID.
The Unit ID is used for stacking. | table | - | .1.3.6.1.4.1.171.12.24.1.11 |
| swPoESystemPowerDisconnectMethod The power management disconnection method. When the total consumed
power exceeds the power budget, the PoE controller initiates port disconnection,
to prevent overloading the powe… | scalar | Enumeration | .1.3.6.1.4.1.171.12.24.1.2 |
| swPoESystemLedMode Specifies if the system mode will be POE or NORMAL. | scalar | Enumeration | .1.3.6.1.4.1.171.12.24.1.4 |
| swPoESystemCtrlLegacyPD The legacy PD detection state. Enables or disables legacy PD detection on all PoE port. | scalar | Enumeration | .1.3.6.1.4.1.171.12.24.1.6 |