swPoESystemInfoPowerRemained
PoE-MIB ·
.1.3.6.1.4.1.171.12.24.2.1.1.3
Object
column
Integer32
The actual momentary remaining power (in watts) in the PoE system.
Context
- MIB
- PoE-MIB
- OID
.1.3.6.1.4.1.171.12.24.2.1.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- swPoESystemInfoEntry
- Table
- swPoESystemInfoTable
- Siblings
- 6
Syntax
Integer32
- Source
- COPS-PR-SPPIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| swPoESystemInfoUnitId This object indicates the device's Unit ID.
A unit ID of zero denotes a stand-alone device. | column | Integer32 | .1.3.6.1.4.1.171.12.24.2.1.1.1 |
| swPoESystemInfoPowerConsumption The actual momentary power consumption (in watts) in the PoE system. | column | Integer32 | .1.3.6.1.4.1.171.12.24.2.1.1.2 |
| swPoESystemInfoPowerLimit The power budget (in watts) of the PoE sytem. | column | Integer32 | .1.3.6.1.4.1.171.12.24.2.1.1.4 |
| swPoESystemInfoPowerDisconnectMethod The power management disconnection method. When the total consumed power
exceeds the power budget, the PoE controller initiates port disconnection
to prevent overloading the power… | column | Enumeration | .1.3.6.1.4.1.171.12.24.2.1.1.5 |
| swPoESystemInfoManagementMode This mode can be either power_limit mode or auto mode.
power_limit: If power supplied to the port exceeds the power limit
specified for it, this port will be shut down.
auto: The… | column | Enumeration | .1.3.6.1.4.1.171.12.24.2.1.1.6 |
| swPoESystemInfoLegacyPD The current status of legacy PD detection. | column | Enumeration | .1.3.6.1.4.1.171.12.24.2.1.1.7 |