sncProtectionTriggerType

PROTECTION-MIB · .1.3.6.1.4.1.1038.130.30.2.1.9

Object

column r/w TriggerCriterion
The value of this field is the criterion to trigger a switch for the Protection Input   
Connection Point. SNC/I uses SF criterion for switching: TU-AIS/TU-LOP for VC12/VC3 ,
AU-AIS/AU-LOP for VC4 and , by extension, ppiLOS and ppiAIS for pdh inputs.
SNC/N uses also SD criterion for switching: SD-V5 for VC12, 
SD-B3 for VC3/VC4.
SNC+LAN adds MS-RDI as switching criterion for LAN connection.
NONE means that just board extractions and some board failures activate switching.

Context

MIB
PROTECTION-MIB
OID
.1.3.6.1.4.1.1038.130.30.2.1.9
Type
column
Access
readwrite
Status
current
Parent
sncEntry
Table
sncTable
Siblings
12

Syntax

TriggerCriterion
Source
TriggerCriterion
Base type
Enumeration

Values & Constraints

Type Values
0none
1sncI
2sncN
3sncIRdi
4sncNRdi

Related Objects

Sibling Objects