portPowerManagementPlugStatus
PERLE-IOLAN-SDS-MIB ·
.1.3.6.1.4.1.1966.12.1.5.23.1.3
Object
column
r/w
ContainerStatus
When you perform a GET on this variable, one of the following values will be returned: 1-Indicates that the container folder is active with no changes. 2-Indicates that the container folder is active with change(s). Once you have completed setting the variables in a folder, you will want to submit your changes to the Device Server. To do this, set the Status variable to 4. If you want to discard the changes, set the Status variable to 6. 4-Indicates that the changes in the container folder are to be submitted to the Device Server. 6-Indicates that the changes in the container folder are to be discarded.
Context
- MIB
- PERLE-IOLAN-SDS-MIB
- OID
.1.3.6.1.4.1.1966.12.1.5.23.1.3- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- portPowerManagementPlugEntry
- Table
- portPowerManagementPlugTable
- Siblings
- 14
Syntax
ContainerStatus
- Source
- ContainerStatus
- Base type
Enumeration
Values & Constraints
Type Values
1 | active |
2 | modified |
4 | applyChanges |
6 | discardChanges |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| portPowerManagementPortIndex The port number | column | PortNumber | .1.3.6.1.4.1.1966.12.1.5.23.1.1 |
| portPowerManagementMonitorTimeout The amount of time to wait after pings, in seconds. | column | Integer32 | .1.3.6.1.4.1.1966.12.1.5.23.1.10 |
| portPowerManagementMonitorRetries The number of times to retry pings. | column | Integer32 | .1.3.6.1.4.1.1966.12.1.5.23.1.11 |
| portPowerManagementMonitorEnableDelay Wait before cycling power, in the event of a monitor timeout. | column | OnOffValue | .1.3.6.1.4.1.1966.12.1.5.23.1.12 |
| portPowerManagementMonitorDelay Amount of time to wait before cycling power, in the event of a monitor timeout. | column | Integer32 | .1.3.6.1.4.1.1966.12.1.5.23.1.13 |
| portPowerManagementMonitorEnableConsoleMsg Display a message on the serial port, in the event of a monitor timeout,
when power cycle delay is enabled.. | column | OnOffValue | .1.3.6.1.4.1.1966.12.1.5.23.1.14 |
| portPowerManagementMonitorEnableEmail Send an email alert, in the event of a monitor timeout,
when power cycle delay is enabled.. | column | OnOffValue | .1.3.6.1.4.1.1966.12.1.5.23.1.15 |
| portPowerManagementPlugIndex The plug number | column | GenericTableIndex | .1.3.6.1.4.1.1966.12.1.5.23.1.2 |
| portPowerManagementPlugName The plug's name. | column | OctetString | .1.3.6.1.4.1.1966.12.1.5.23.1.4 |
| portPowerManagementPlugPowerUpInterval The plug's power up delay. | column | Enumeration | .1.3.6.1.4.1.1966.12.1.5.23.1.5 |
| portPowerManagementPlugDefaultState the plug's default state. | column | OnOffValue | .1.3.6.1.4.1.1966.12.1.5.23.1.6 |
| portPowerManagementDSLine the DS line number which the device on this plug is connected to(0:none, >0:corresponding to the
line number. | column | PortNumber | .1.3.6.1.4.1.1966.12.1.5.23.1.7 |
| portPowerManagementMonitorHost The name of a host to monitor. If the host fails to respond to pings,
this plug's power will be cycled. Set to a blank string to disable
this feature. | column | OctetString | .1.3.6.1.4.1.1966.12.1.5.23.1.8 |
| portPowerManagementMonitorInterval The time between pings, in minutes. | column | Integer32 | .1.3.6.1.4.1.1966.12.1.5.23.1.9 |