transferSwitchConfigurationEntry
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.9.3.1
Object
row
An entry containing objects for a particular transfer switch.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.9.3.1- Type
- row
- Status
- current
- Parent
- transferSwitchConfigurationTable
- Table
- transferSwitchConfigurationTable
- Children
- 12
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| transferSwitchId A unique value for each transfer switch. Its value
ranges between 1 and the value of transferSwitchCount. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.9.3.1.1 |
| transferSwitchLabel The label on the PDU identifying the transfer switch. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.9.3.1.2 |
| transferSwitchAutoReTransferEnabled Enables or disables automatic retransfer from the standby inlet to
the preferred inlet after power has been restored. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.9.3.1.20 |
| transferSwitchAutoReTransferWaitTime The delay for automatic retransfers. Retransfer occurs this many
seconds after the condition causing the original transfer has been
corrected. | column | Unsigned32 | .1.3.6.1.4.1.13742.6.3.9.3.1.21 |
| transferSwitchAutoReTransferRequiresPhaseSync Enables or disables automatic retransfer in case the two inlets are
not synchronized. If set to True, automatic retransfer is inhibited while
a phase sync alarm is present, i.e. t… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.9.3.1.22 |
| transferSwitchFrontPanelManualTransferButtonEnabled Enables or disables the Manual Transfer button on the unit's front panel. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.3.9.3.1.23 |
| transferSwitchCapabilities A bit string indicating which sensors are available for the transfer switch. | column | Bits | .1.3.6.1.4.1.13742.6.3.9.3.1.24 |
| transferSwitchName The user-defined name of the transfer switch. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.13742.6.3.9.3.1.3 |
| transferSwitchPowerSource1 This object allows discovery of how the PDU is wired. It indicates the
transfer switch's first power source, typically a fuse.
It contains the OID of an overCurrent… | column | SNMPv2-TCRowPointer | .1.3.6.1.4.1.13742.6.3.9.3.1.31 |
| transferSwitchPowerSource2 This object allows discovery of how the PDU is wired. It indicates the
transfer switch's second power source, typically a fuse.
It contains the OID of an overCurren… | column | SNMPv2-TCRowPointer | .1.3.6.1.4.1.13742.6.3.9.3.1.32 |
| transferSwitchPreferredInlet The preferred inlet. This is the inlet to be selected in case both
inlets have acceptable power. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.9.3.1.4 |
| transferSwitchPoleCount The number of poles. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.9.3.1.5 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduId A unique value for each PDU or power meter.
For BCM2 and PMC, pduId can be:
- 0 for the main controller
- The meter ID (rotary switch) for power meter
For a… | column | Integer32 | .1.3.6.1.4.1.13742.6.3.2.1.1.1 |
| transferSwitchId A unique value for each transfer switch. Its value
ranges between 1 and the value of transferSwitchCount. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.9.3.1.1 |