powerMeterConfigurationEntry
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.10.2.1
Object
row
An entry containing configuration objects for power meters and panels.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.10.2.1- Type
- row
- Status
- current
- Parent
- powerMeterConfigurationTable
- Table
- powerMeterConfigurationTable
- Children
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| powerMeterPhaseCTRating The rating of the phase CT in Amps, or 0 if no CT is present.
At present, read-only access;
see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2 | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.10.2.1.2 |
| powerMeterNeutralCTRating The rating of the neutral CT in Amps, or 0 if no CT is present.
At present, read-only access;
see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2 | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.10.2.1.3 |
| powerMeterEarthCTRating The rating of the earth CT in Amps, or 0 if no CT is present.
At present, read-only access;
see MIN-ACCESS in MODULE-COMPLIANCE ModulecomplianceRev2 | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.10.2.1.4 |
| powerMeterBranchCount The maximum number of circuits supported by the panel.
This can be used to distinguish between panels (>0) and power meters (0).
See circuitCount for the number of … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.10.2.1.5 |
| powerMeterPanelPositions The number of circuit positions in the panel, or 0 for power meters.
Its value is specified by the user when configuring a panel | column | Integer32 | .1.3.6.1.4.1.13742.6.3.10.2.1.6 |
| powerMeterPanelLayout The panel circuit position layout: one or two columns.
This is valid only for panels, the value is -1 for power meters. | column | PanelLayoutEnumeration | .1.3.6.1.4.1.13742.6.3.10.2.1.7 |
| powerMeterPanelNumbering The panel circuit position numbering scheme: odd/even or sequential.
This is valid only for panels, the value is -1 for power meters. | column | PanelNumberingEnumeration | .1.3.6.1.4.1.13742.6.3.10.2.1.8 |
| powerMeterType The power meter type: 3-phase, single-phase or split-phase. | column | PowerMeterTypeEnumeration | .1.3.6.1.4.1.13742.6.3.10.2.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduId A unique value for each PDU or power meter.
For BCM2 and PMC, pduId can be:
- 0 for the main controller
- The meter ID (rotary switch) for power meter
For a… | column | Integer32 | .1.3.6.1.4.1.13742.6.3.2.1.1.1 |