measurementsTransferSwitchSensorMaxValue
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.5.7.3.1.11
Object
column
SNMPv2-SMIUnsigned32
The maximum value of sensor reading since last reset as an unsigned integer The value of this OID variable should be scaled by transferSwitchSensorDecimalDigits. For example, if the value is 1 and transferSwitchSensorDecimalDigits is 2, then actual value is 0.01. This value will wrap around if the scaled sensor reading exceeds 4294967295. It is undefined for sensors which can have negative readings. This parameter does not apply to sensors without a numerical reading, or sensors that are not present or are in an unavailable state.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.5.7.3.1.11- Type
- column
- Access
- readonly
- Status
- current
- Parent
- transferSwitchSensorMeasurementsEntry
- Table
- transferSwitchSensorMeasurementsTable
- Siblings
- 12
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| measurementsTransferSwitchSensorMinTimeStamp The timestamp of last change of the minimum value of sensor reading
provided as measurementTransferSwitchSensor[Signed]MinValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.7.3.1.10 |
| measurementsTransferSwitchSensorSignedMaxValue The maximum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
transferSwitchSensorDecimalDigits. For example, if the … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.7.3.1.12 |
| measurementsTransferSwitchSensorMaxTimeStamp The timestamp of last change of the maximum value of sensor reading
provided as measurementTransferSwitchSensor[Signed]MaxValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.7.3.1.13 |
| measurementsTransferSwitchSensorMinMaxResetTimeStamp The timestamp of last reset of all minimum and maximum values of sensor reading
including their timestamps, provided as measurementsTransferSwitchSensor[Signed]{Min|Max}{Value|Tim… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.7.3.1.14 |
| measurementsTransferSwitchSensorIsAvailable The sensor is present. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.7.3.1.2 |
| measurementsTransferSwitchSensorState The sensor state. | column | SensorStateEnumeration | .1.3.6.1.4.1.13742.6.5.7.3.1.3 |
| measurementsTransferSwitchSensorValue The sensor reading as an unsigned integer.
The value of this OID variable should be scaled by
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
transferSwitchS… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.7.3.1.4 |
| measurementsTransferSwitchSensorTimeStamp The timestamp for reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.7.3.1.5 |
| measurementsTransferSwitchSensorSignedValue The sensor reading as a signed integer.
The value of this OID variable should be scaled by
transferSwitchSensorDecimalDigits. For example, if the value is 1 and
transferSwitchSens… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.7.3.1.6 |
| measurementsTransferSwitchSensorMinMaxValid The minimum and maximum values of sensor reading and their timestamps
provided as measurementsTransferSwitchSensor[Signed]{Min|Max}{Value|TimeStamp} are valid | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.7.3.1.7 |
| measurementsTransferSwitchSensorMinValue The minimum value of sensor reading since last reset as an unsigned integer
The value of this OID variable should be scaled by
transferSwitchSensorDecimalDigits. For example, if t… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.7.3.1.8 |
| measurementsTransferSwitchSensorSignedMinValue The minimum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
transferSwitchSensorDecimalDigits. For example, if the … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.7.3.1.9 |