measurementsOutletGroupSensorMinValue
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.5.9.3.1.8
Object
column
SNMPv2-SMIUnsigned32
The minimum value of sensor reading since last reset as an unsigned integer The value of this OID variable should be scaled by outletGroupSensorDecimalDigits. For example, if the value is 1 and outletGroupSensorDecimalDigits is 2, then actual value is 0.01. This value will wrap around if the scaled sensor reading exceeds 4294967295. It is undefined for sensors which can have negative readings. This parameter does not apply to sensors without a numerical reading, or sensors that are not present or are in an unavailable state.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.5.9.3.1.8- Type
- column
- Access
- readonly
- Status
- current
- Parent
- outletGroupSensorMeasurementsEntry
- Table
- outletGroupSensorMeasurementsTable
- Siblings
- 12
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| measurementsOutletGroupSensorMinTimeStamp The timestamp of last change of the minimum value of sensor reading
provided as measurementOutletGroupSensor[Signed]MinValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.9.3.1.10 |
| measurementsOutletGroupSensorMaxValue The maximum value of sensor reading since last reset as an unsigned integer
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.9.3.1.11 |
| measurementsOutletGroupSensorSignedMaxValue The maximum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the val… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.9.3.1.12 |
| measurementsOutletGroupSensorMaxTimeStamp The timestamp of last change of the maximum value of sensor reading
provided as measurementOutletGroupSensor[Signed]MaxValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.9.3.1.13 |
| measurementsOutletGroupSensorMinMaxResetTimeStamp The timestamp of last reset of all minimum and maximum values of sensor reading
including their timestamps, provided as measurementsOutletGroupSensor[Signed]{Min|Max}{Value|TimeSt… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.9.3.1.14 |
| measurementsOutletGroupSensorIsAvailable The sensor is present. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.9.3.1.2 |
| measurementsOutletGroupSensorState The sensor state. | column | SensorStateEnumeration | .1.3.6.1.4.1.13742.6.5.9.3.1.3 |
| measurementsOutletGroupSensorValue The sensor reading as an unsigned integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroupSensorD… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.9.3.1.4 |
| measurementsOutletGroupSensorTimeStamp The timestamp for reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.9.3.1.5 |
| measurementsOutletGroupSensorSignedValue The sensor reading as a signed integer.
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the value is 1 and
outletGroupSensorDeci… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.9.3.1.6 |
| measurementsOutletGroupSensorMinMaxValid The minimum and maximum values of sensor reading and their timestamps
provided as measurementsOutletGroupSensor[Signed]{Min|Max}{Value|TimeStamp} are valid | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.9.3.1.7 |
| measurementsOutletGroupSensorSignedMinValue The minimum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
outletGroupSensorDecimalDigits. For example, if the val… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.9.3.1.9 |