measurementsInletPoleSensorMinMaxValid
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.5.2.4.1.7
Object
column
SNMPv2-TCTruthValue
The minimum and maximum values of sensor reading and their timestamps
provided as measurementsInletPoleSensor[Signed]{Min|Max}{Value|TimeStamp} are valid
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.5.2.4.1.7- Type
- column
- Access
- readonly
- Status
- current
- Parent
- inletPoleSensorMeasurementsEntry
- Table
- inletPoleSensorMeasurementsTable
- Siblings
- 12
Values & Constraints
Type Values
1 | true |
2 | false |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| measurementsInletPoleSensorMinTimeStamp The timestamp of last change of the minimum value of sensor reading
provided as measurementInletPoleSensor[Signed]MinValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.4.1.10 |
| measurementsInletPoleSensorMaxValue The maximum value of sensor reading since last reset as an unsigned integer
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the va… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.4.1.11 |
| measurementsInletPoleSensorSignedMaxValue The maximum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.2.4.1.12 |
| measurementsInletPoleSensorMaxTimeStamp The timestamp of last change of the maximum value of sensor reading
provided as measurementInletPoleSensor[Signed]MaxValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.4.1.13 |
| measurementsInletPoleSensorMinMaxResetTimeStamp The timestamp of last reset of all minimum and maximum values of sensor reading
including their timestamps, provided as measurementsInletPoleSensor[Signed]{Min|Max}{Value|TimeStam… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.4.1.14 |
| measurementsInletPoleSensorIsAvailable The sensor is present. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.2.4.1.2 |
| measurementsInletPoleSensorState The sensor state. | column | SensorStateEnumeration | .1.3.6.1.4.1.13742.6.5.2.4.1.3 |
| measurementsInletPoleSensorValue The sensor reading as an unsigned integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSensorDecim… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.4.1.4 |
| measurementsInletPoleSensorTimeStamp The timestamp for reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.4.1.5 |
| measurementsInletPoleSensorSignedValue The sensor reading as a signed integer.
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value is 1 and
inletPoleSensorDecimalD… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.2.4.1.6 |
| measurementsInletPoleSensorMinValue The minimum value of sensor reading since last reset as an unsigned integer
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the va… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.4.1.8 |
| measurementsInletPoleSensorSignedMinValue The minimum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
inletPoleSensorDecimalDigits. For example, if the value… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.2.4.1.9 |