measurementsInletLinePairSensorMinValue
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.5.2.5.1.8
Object
column
SNMPv2-SMIUnsigned32
The minimum value of sensor reading since last reset as an unsigned integer The value of this OID variable should be scaled by inletLinePairSensorDecimalDigits. For example, if the value is 1 and inletLinePairSensorDecimalDigits is 2, then actual value is 0.01. This value will wrap around if the scaled sensor reading exceeds 4294967295. It is undefined for sensors which can have negative readings. This parameter does not apply to sensors without a numerical reading, or sensors that are not present or are in an unavailable state.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.5.2.5.1.8- Type
- column
- Access
- readonly
- Status
- current
- Parent
- inletLinePairSensorMeasurementsEntry
- Table
- inletLinePairSensorMeasurementsTable
- Siblings
- 12
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| measurementsInletLinePairSensorMinTimeStamp The timestamp of last change of the minimum value of sensor reading
provided as measurementInletLinePairSensor[Signed]MinValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.5.1.10 |
| measurementsInletLinePairSensorMaxValue The maximum value of sensor reading since last reset as an unsigned integer
The value of this OID variable should be scaled by
inletLinePairSensorDecimalDigits. For example, if th… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.5.1.11 |
| measurementsInletLinePairSensorSignedMaxValue The maximum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
inletLinePairSensorDecimalDigits. For example, if the v… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.2.5.1.12 |
| measurementsInletLinePairSensorMaxTimeStamp The timestamp of last change of the maximum value of sensor reading
provided as measurementInletLinePairSensor[Signed]MaxValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.5.1.13 |
| measurementsInletLinePairSensorMinMaxResetTimeStamp The timestamp of last reset of all minimum and maximum values of sensor reading
including their timestamps, provided as measurementsInletLinePairSensor[Signed]{Min|Max}{Value|Time… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.5.1.14 |
| measurementsInletLinePairSensorIsAvailable The sensor is present. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.2.5.1.2 |
| measurementsInletLinePairSensorState The sensor state. | column | SensorStateEnumeration | .1.3.6.1.4.1.13742.6.5.2.5.1.3 |
| measurementsInletLinePairSensorValue The sensor reading as an unsigned integer.
The value of this OID variable should be scaled by
inletLinePairSensorDecimalDigits. For example, if the value is 1 and
inletLinePairSen… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.5.1.4 |
| measurementsInletLinePairSensorTimeStamp The timestamp for reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.2.5.1.5 |
| measurementsInletLinePairSensorSignedValue The sensor reading as a signed integer.
The value of this OID variable should be scaled by
inletLinePairSensorDecimalDigits. For example, if the value is 1 and
inletLinePairSensor… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.2.5.1.6 |
| measurementsInletLinePairSensorMinMaxValid The minimum and maximum values of sensor reading and their timestamps
provided as measurementsInletLinePairSensor[Signed]{Min|Max}{Value|TimeStamp} are valid | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.2.5.1.7 |
| measurementsInletLinePairSensorSignedMinValue The minimum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
inletLinePairSensorDecimalDigits. For example, if the v… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.2.5.1.9 |