measurementsCircuitPoleSensorMaxTimeStamp
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.5.8.4.1.13
Object
column
SNMPv2-SMIUnsigned32
The timestamp of last change of the maximum value of sensor reading provided as measurementCircuitPoleSensor[Signed]MaxValue
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.5.8.4.1.13- Type
- column
- Access
- readonly
- Status
- current
- Parent
- circuitPoleSensorMeasurementsEntry
- Table
- circuitPoleSensorMeasurementsTable
- Siblings
- 12
Syntax
SNMPv2-SMIUnsigned32
- Source
- SNMPv2-SMIUnsigned32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| measurementsCircuitPoleSensorMinTimeStamp The timestamp of last change of the minimum value of sensor reading
provided as measurementCircuitPoleSensor[Signed]MinValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.8.4.1.10 |
| measurementsCircuitPoleSensorMaxValue The maximum value of sensor reading since last reset as an unsigned integer
The value of this OID variable should be scaled by
circuitPoleSensorDecimalDigits. For example, if the … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.8.4.1.11 |
| measurementsCircuitPoleSensorSignedMaxValue The maximum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
circuitPoleSensorDecimalDigits. For example, if the val… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.8.4.1.12 |
| measurementsCircuitPoleSensorMinMaxResetTimeStamp The timestamp of last reset of all minimum and maximum values of sensor reading
including their timestamps, provided as measurementsCircuitPoleSensor[Signed]{Min|Max}{Value|TimeSt… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.8.4.1.14 |
| measurementsCircuitPoleSensorIsAvailable The sensor is present. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.8.4.1.2 |
| measurementsCircuitPoleSensorState The sensor state. | column | SensorStateEnumeration | .1.3.6.1.4.1.13742.6.5.8.4.1.3 |
| measurementsCircuitPoleSensorValue The sensor reading as an unsigned integer.
The value of this OID variable should be scaled by
circuitPoleSensorDecimalDigits. For example, if the value is 1 and
circuitPoleSensorD… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.8.4.1.4 |
| measurementsCircuitPoleSensorTimeStamp The timestamp for reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.8.4.1.5 |
| measurementsCircuitPoleSensorSignedValue The sensor reading as a signed integer.
The value of this OID variable should be scaled by
circuitPoleSensorDecimalDigits. For example, if the value is 1 and
circuitPoleSensorDeci… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.8.4.1.6 |
| measurementsCircuitPoleSensorMinMaxValid The minimum and maximum values of sensor reading and their timestamps
provided as measurementsCircuitPoleSensor[Signed]{Min|Max}{Value|TimeStamp} are valid | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.8.4.1.7 |
| measurementsCircuitPoleSensorMinValue The minimum value of sensor reading since last reset as an unsigned integer
The value of this OID variable should be scaled by
circuitPoleSensorDecimalDigits. For example, if the … | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.8.4.1.8 |
| measurementsCircuitPoleSensorSignedMinValue The minimum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
circuitPoleSensorDecimalDigits. For example, if the val… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.8.4.1.9 |