externalSensorTypeDefaultThresholdsEntry
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.3.6.4.1
Object
row
An entry containing default thresholds for a sensor type.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.3.6.4.1- Type
- row
- Status
- current
- Parent
- externalSensorTypeDefaultThresholdsTable
- Table
- externalSensorTypeDefaultThresholdsTable
- Children
- 11
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| externalSensorTypeDefaultUnit The unit in which the default threshold parameters are specified. | column | SensorUnitsEnumeration | .1.3.6.1.4.1.13742.6.3.6.4.1.10 |
| externalSensorTypeDefaultDecimalDigits The number of digits displayed to the right of the decimal point. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.6.4.1.11 |
| externalSensorTypeDefaultMaximum The largest possible threshold value for this sensor type.
The value of this OID variable should be scaled by
externalSensorTypeDefaultDecimalDigits. For example, if the value
is… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.6.4.1.12 |
| externalSensorTypeDefaultMinimum The smallest possible threshold value for this sensor type.
The value of this OID variable should be scaled by
externalSensorTypeDefaultDecimalDigits. For example, if the value
i… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.6.4.1.13 |
| externalSensorTypeDefaultHysteresis The hysteresis used when crossing a threshold towards the normal state.
The value of this OID variable should be scaled by
externalSensorTypeDefaultDecimalDigits. For example, if… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.3.6.4.1.3 |
| externalSensorTypeDefaultStateChangeDelay The delay measured in samples before a state is asserted.
If the value is zero, then the state is asserted as soon as
it is detected; if it is non-zero, say n, then the assertion
… | column | Unsigned32 | .1.3.6.1.4.1.13742.6.3.6.4.1.4 |
| externalSensorTypeDefaultLowerCriticalThreshold The lower critical threshold
The value of this OID variable should be scaled by
externalSensorTypeDefaultDecimalDigits. For example, if the value is 1 and
externalSensorTypeDefau… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.6.4.1.5 |
| externalSensorTypeDefaultLowerWarningThreshold The lower warning threshold
The value of this OID variable should be scaled by
externalSensorTypeDefaultDecimalDigits. For example, if the value is 1 and
externalSensorTypeDefaul… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.6.4.1.6 |
| externalSensorTypeDefaultUpperCriticalThreshold The upper critical threshold
The value of this OID variable should be scaled by
externalSensorTypeDefaultDecimalDigits. For example, if the value is 1 and
externalSensorTypeDefau… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.6.4.1.7 |
| externalSensorTypeDefaultUpperWarningThreshold The upper warning threshold
The value of this OID variable should be scaled by
externalSensorTypeDefaultDecimalDigits. For example, if the value is 1 and
externalSensorTypeDefaul… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.3.6.4.1.8 |
| externalSensorTypeDefaultEnabledThresholds A bit string indicating which thresholds are enabled. | column | Bits | .1.3.6.1.4.1.13742.6.3.6.4.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduId A unique value for each PDU or power meter.
For BCM2 and PMC, pduId can be:
- 0 for the main controller
- The meter ID (rotary switch) for power meter
For a… | column | Integer32 | .1.3.6.1.4.1.13742.6.3.2.1.1.1 |
| sensorType The type of sensor. | column | SensorTypeEnumeration | .1.3.6.1.4.1.13742.6.3.2.5.1.1 |