externalSensorMeasurementsEntry
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.5.5.3.1
Object
row
An entry containing external sensor measurement objects.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.5.5.3.1- Type
- row
- Status
- current
- Parent
- externalSensorMeasurementsTable
- Table
- externalSensorMeasurementsTable
- Children
- 10
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| measurementsExternalSensorMinTimeStamp The timestamp of last change of the minimum value of sensor reading
provided as measurementExternalSensor[Signed]MinValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.5.3.1.10 |
| measurementsExternalSensorMaxValue The maximum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
externalSensorDecimalDigits. For example, if the value … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.5.3.1.11 |
| measurementsExternalSensorMaxTimeStamp The timestamp of last change of the maximum value of sensor reading
provided as measurementExternalSensor[Signed]MaxValue | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.5.3.1.13 |
| measurementsExternalSensorMinMaxResetTimeStamp The timestamp of last reset of all minimum and maximum values of sensor reading
including their timestamps, provided as measurementsExternalSensor[Signed]{Min|Max}{Value|TimeStamp… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.5.3.1.14 |
| measurementsExternalSensorIsAvailable The sensor is present. | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.5.3.1.2 |
| measurementsExternalSensorState The sensor state. | column | SensorStateEnumeration | .1.3.6.1.4.1.13742.6.5.5.3.1.3 |
| measurementsExternalSensorValue The sensor reading as a signed integer.
The value of this OID variable should be scaled by
externalSensorDecimalDigits. For example, if the value is 1 and
externalSensorDecimalDig… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.5.3.1.4 |
| measurementsExternalSensorTimeStamp The timestamp for reading. | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.5.5.3.1.5 |
| measurementsExternalSensorMinMaxValid The minimum and maximum values of sensor reading and their timestamps
provided as measurementsExternalSensor[Signed]{Min|Max}{Value|TimeStamp} are valid | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.5.5.3.1.7 |
| measurementsExternalSensorMinValue The minimum value of sensor reading since last reset as a signed integer
The value of this OID variable should be scaled by
externalSensorDecimalDigits. For example, if the value … | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.5.5.3.1.8 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduId A unique value for each PDU or power meter.
For BCM2 and PMC, pduId can be:
- 0 for the main controller
- The meter ID (rotary switch) for power meter
For a… | column | Integer32 | .1.3.6.1.4.1.13742.6.3.2.1.1.1 |
| sensorID A unique value for each sensor. Its value