circuitSensorLogEntry
PDU2-MIB ·
.1.3.6.1.4.1.13742.6.6.8.3.1
Object
row
An entry containing log objects for a circuit sensor.
Context
- MIB
- PDU2-MIB
- OID
.1.3.6.1.4.1.13742.6.6.8.3.1- Type
- row
- Status
- current
- Parent
- circuitSensorLogTable
- Table
- circuitSensorLogTable
- Children
- 8
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| logCircuitSensorDataAvailable Is data available for this sensor during this measurement period? | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.13742.6.6.8.3.1.2 |
| logCircuitSensorState The most critical sensor state during this measurement period. | column | SensorStateEnumeration | .1.3.6.1.4.1.13742.6.6.8.3.1.3 |
| logCircuitSensorAvgValue The average sensor reading for the log period as an unsigned integer.
The value of this OID variable should be scaled by
circuitSensorDecimalDigits. For example, if the value is 1… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.6.8.3.1.4 |
| logCircuitSensorMaxValue The maximum sensor reading for the log period as an unsigned integer.
The value of this OID variable should be scaled by
circuitSensorDecimalDigits. For example, if the value is 1… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.6.8.3.1.5 |
| logCircuitSensorMinValue The minimum sensor reading for the log period as an unsigned integer.
The value of this OID variable should be scaled by
circuitSensorDecimalDigits. For example, if the value is 1… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.13742.6.6.8.3.1.6 |
| logCircuitSensorSignedAvgValue The average sensor reading for the log period as a signed integer.
The value of this OID variable should be scaled by
circuitSensorDecimalDigits. For example, if the value is 1 an… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.6.8.3.1.7 |
| logCircuitSensorSignedMaxValue The maximum sensor reading for the log period as a signed integer.
The value of this OID variable should be scaled by
circuitSensorDecimalDigits. For example, if the value is 1 an… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.6.8.3.1.8 |
| logCircuitSensorSignedMinValue The minimum sensor reading for the log period as a signed integer.
The value of this OID variable should be scaled by
circuitSensorDecimalDigits. For example, if the value is 1 an… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.13742.6.6.8.3.1.9 |
Indexes
| Object | Type | Syntax | OID |
|---|---|---|---|
| pduId A unique value for each PDU or power meter.
For BCM2 and PMC, pduId can be:
- 0 for the main controller
- The meter ID (rotary switch) for power meter
For a… | column | Integer32 | .1.3.6.1.4.1.13742.6.3.2.1.1.1 |
| circuitId A unique value for each circuit. Its value is the smallest panel
position occupied by the circuit. | column | Integer32 | .1.3.6.1.4.1.13742.6.3.11.2.1.1 |
| sensorType The type of sensor. | column | SensorTypeEnumeration | .1.3.6.1.4.1.13742.6.3.2.5.1.1 |
| logIndex A unique value for each entry in the log. Its value
ranges between 1 and the value of logSize. | column | Integer32 | .1.3.6.1.4.1.13742.6.6.1.2.1.1 |