dcRectifierGroupStartupLimitTime
ORION-BASE-MIB ·
.1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.12
Object
For details see dcRectifierGroupStartupVoltage.
Context
- MIB
- ORION-BASE-MIB
- OID
.1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.12- Type
- column
- Access
- readwrite
- Status
- current
- Units
- 10 ms
- Parent
- dcRectifierGroupEntry
- Table
- dcRectifierGroupTable
- Siblings
- 14
Syntax
10 ms SNMPv2-SMIGauge32
- Source
- SNMPv2-SMIGauge32
- Base type
Unsigned32
Values & Constraints
Type Constraints
range: 0..4294967295
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dcRectifierGroupIndex Table index. | column | Integer32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.1 |
| dcRectifierGroupStartupCurrentLimit For details see dcRectifierGroupStartupVoltage. | column | 100 mA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.10 |
| dcRectifierGroupStartupPowerLimit For details see dcRectifierGroupStartupVoltage. | column | 1 W SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.11 |
| dcRectifierGroupPowerupDelay This parameter is used after a mains failure to
delay the start-up of all rectifiers. | column | 10 ms SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.13 |
| dcRectifierGroupPowerupTime This parameter used after a mains failure and allows
defining a time within all rectifiers needs to start-up
one after another. | column | 10 ms SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.14 |
| dcRectifierGroupUmaxOff Overvoltage protection value. | column | 10 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.15 |
| dcRectifierGroupName Rectifier group name to identify an individual device
parameter set. | column | OctetString | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.2 |
| dcRectifierGroupRectifierType Rectifier type defined for this group. | column | Enumeration | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.3 |
| dcRectifierGroupDefaultVoltage This default voltage is used by rectifiers when there
is no connection to ORION. | column | 10 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.4 |
| dcRectifierGroupDefaultCurrentLimit This default current limit is used by rectifiers when there
is no connection to ORION. | column | 100 mA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.5 |
| dcRectifierGroupDefaultPowerLimit This default power limit is used by rectifiers when there
is no connection to ORION. | column | 1 W SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.6 |
| dcRectifierGroupInputLowOff Threshold for low AC input voltage. It can is used to
adjust the behaviour of the power system to the available
AC network limitation. | column | 100 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.7 |
| dcRectifierGroupInputLowOn For details see dcRectifierGroupInputLowOff. | column | 100 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.8 |
| dcRectifierGroupStartupVoltage Startup parameters are the values that rectifiers use
during the start-up phase. These parameters allow starting
the system smoothly after a mains failure even on a
discharged … | column | 10 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.4.5.1.9 |