dcInverterGroupInputVoltage2
ORION-BASE-MIB ·
.1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.10
Object
Input voltage line 2 - in three phase system only
Context
- MIB
- ORION-BASE-MIB
- OID
.1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.10- Type
- column
- Access
- readonly
- Status
- current
- Units
- 100 mV
- Parent
- dcInverterGroupEntry
- Table
- dcInverterGroupTable
- Siblings
- 21
Syntax
100 mV SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dcInverterGroupIndex Table index. | column | Integer32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.1 |
| dcInverterGroupInputVoltage3 Input voltage line 3 - in three phase system only | column | 100 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.11 |
| dcInverterGroupInputApparentPower1 Input power line 1 | column | 1 VA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.12 |
| dcInverterGroupInputApparentPower2 Input power line 2 - in three phase system only | column | 1 VA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.13 |
| dcInverterGroupInputApparentPower3 Input power line 3 - in three phase system only | column | 1 VA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.14 |
| dcInverterGroupInputFrequency Input frequency | column | 10 mHz SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.15 |
| dcInverterGroupOutputVoltage1 Output voltage line 1 | column | 100 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.16 |
| dcInverterGroupOutputVoltage2 Output voltage line 2 - in three phase system only | column | 100 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.17 |
| dcInverterGroupOutputVoltage3 Output voltage line 3 - in three phase system only | column | 100 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.18 |
| dcInverterGroupOutputApparentPower1 Output apparent power line 1 | column | 1 VA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.19 |
| dcInverterGroupState This is the alarm state of the inverter system. | column | Enumeration | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.2 |
| dcInverterGroupOutputApparentPower2 Output apparent power line 2 - in three phase system only | column | 1 VA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.20 |
| dcInverterGroupOutputApparentPower3 Output apparent power line 3 - in three phase system only | column | 1 VA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.21 |
| dcInverterGroupOutputFrequency Output frequency | column | 10 mHz SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.22 |
| dcInverterGroupLoadPosition Shows where is the load positioned in the system. | column | Enumeration | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.3 |
| dcInverterGroupNbrOfConfigInverters The system is configure to operate this number of inverters at maximum. | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.4 |
| dcInverterGroupNbrOfPresentInverters Number of inverters actually present in the system. | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.5 |
| dcInverterGroupPhase This is the alarm state of the inverter system. | column | SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.6 |
| dcInverterGroupDcVoltage Input DC voltage | column | 10 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.7 |
| dcInverterGroupInputDcPower Input DC Power | column | 1 W SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.8 |
| dcInverterGroupInputVoltage1 Input voltage line 1 | column | 100 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.15.1.1.9 |