dcBatteryTestUsupport
ORION-BASE-MIB ·
.1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.1
Object
Support charge voltage for the battery.
Context
- MIB
- ORION-BASE-MIB
- OID
.1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.1- Type
- scalar
- Access
- readonly
- Status
- obsolete
- Units
- 10 mV
- Parent
- dcBatteryTestParameter
- Siblings
- 11
Syntax
10 mV SNMPv2-SMIInteger32
- Source
- SNMPv2-SMIInteger32
- Base type
Integer32
Values & Constraints
Type Constraints
range: -2147483648..2147483647
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| dcBatteryTestIntervalEnabled obsolete Enable/disable interval. For more details see dcBatteryTestInterval. | scalar | Enumeration | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.10 |
| dcBatteryTestStartTimeFrom obsolete Defines start time window for battery test. The possible time window
is defined as the range between dcBatteryTestStartTimeFrom and
dcBatteryTestStartTimeTo. The value is in the… | scalar | OctetString | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.11 |
| dcBatteryTestStartTimeTo obsolete For details see dcBatteryTestStartTimeFrom. | scalar | OctetString | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.12 |
| dcBatteryTestDuration obsolete Battery test duration. | scalar | minute SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.2 |
| dcBatteryTestInterval obsolete Minimal time between programmed battery tests as start
condition. | scalar | days SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.3 |
| dcBatteryTestDischargeCurrent obsolete Battery discharge current. The maximum value 2147483647
is used to indicate an invalid value. | scalar | 100 mA SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.4 |
| dcBatteryTestMinDuration obsolete Minimum battery test duration during which time a battery test
is not stopped in case of a voltage below the support voltage or
a current difference higher than the specified va… | scalar | minutes SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.5 |
| dcBatteryTestVoltageWithinUfloat obsolete Battery voltage must be within Ufloat +/- set voltage for a
given time (see also dcBatteryTestVoltageWithinUfloatPeriod)
in order to start a battery test. | scalar | 10 mV SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.6 |
| dcBatteryTestVoltageWithinUfloatPeriod obsolete For details see dcBatteryTestVoltageWithinUfloat parameter. | scalar | days SNMPv2-SMIGauge32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.7 |
| dcBatteryTestTempFrom obsolete Battery temperature must be within temperature range given by
dcBatteryTestTempFrom and dcBatteryTestTempTo, so that a battery
test can be started. | scalar | 0.1 degree SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.8 |
| dcBatteryTestTempTo obsolete For details see dcBatteryTestTempFrom parameter. | scalar | 0.1 degree SNMPv2-SMIInteger32 | .1.3.6.1.4.1.20246.2.3.1.1.1.2.5.2.1.9 |