optIfODUkTSinkLockSignalAdminState

OPT-IF-MIB · .1.3.6.1.2.1.10.133.1.9.1.1.12

Object

column r/w Enumeration
Provides the capability to provision the LOCK signal, which
is one of the ODUk maintenance signals, at the ODUKT sink.  When
a Tandem Connection endpoint is set to admin state locked,
it inserts the ODUk-LCK signal in the sink direction.
              
This object is applicable only when the value of
optIfODUkTtpPresent is false(2) and also either one of the
following three cases holds:
  (i) optIfODUkDirectionality has the value bidirectional(3), or
  (ii) optIfODUkDirectionality has the value sink(1) and
       optIfODUkTCodirectional has the value true(1), or
  (iii) optIfODUkDirectionality has the value source(3) and
        optIfODUkTCodirectional has the value false(2).
It must not be instantiated in rows for all other cases.

Context

MIB
OPT-IF-MIB
OID
.1.3.6.1.2.1.10.133.1.9.1.1.12
Type
column
Access
readwrite
Status
current
Parent
optIfODUkTConfigEntry
Table
optIfODUkTConfigTable
Siblings
14

Syntax

Enumeration

Values & Constraints

Enumerated Values
1locked
2normal

Related Objects

Sibling Objects