optIfODUkTNimDirectionality

OPT-IF-MIB · .1.3.6.1.2.1.10.133.1.9.2.1.2

Object

column OptIfSinkOrSource
Specifies the monitor point for the ODUk TCM non-intrusive
monitoring function.  The value source(2) is not allowed
if the corresponding instance of optIfODUkDirectionality
has the value sink(1), and the value sink(1) is not allowed
if the corresponding instance of optIfODUkDirectionality
has the value source(2).  Either the value sink(1) or
source(2) is allowed if the corresponding instance of
optIfODUkDirectionality has the value bidirectional(3).
The value sink(1) means monitoring at the sink direction
TCM signal of the ODUk CTP.
The value source(2) means monitoring at the source direction
path signal of the ODUk CTP.

Context

MIB
OPT-IF-MIB
OID
.1.3.6.1.2.1.10.133.1.9.2.1.2
Type
column
Access
noaccess
Status
current
Parent
optIfODUkTNimConfigEntry
Table
optIfODUkTNimConfigTable
Siblings
10

Syntax

OptIfSinkOrSource
Source
OptIfSinkOrSource
Base type
Enumeration

Values & Constraints

Type Values
1sink
2source

Related Objects

Sibling Objects