chassistype
OMNITRON-MIB ·
.1.3.6.1.4.1.7342.1.1.1.3
Object
column
Integer32
Type of chassis: 1 = 19 module chassis 2 = 2 module chassis 3 = 5 module chassis 4 = 1 module chassis 5 = stand alone chassis 6 = 1-module redundant power chassis
Context
- MIB
- OMNITRON-MIB
- OID
.1.3.6.1.4.1.7342.1.1.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- chassisEntry
- Table
- chassisTable
- Siblings
- 20
Syntax
Integer32
Values & Constraints
Object Constraints
range: 1-6
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| chassisnum The chassis where the module resides. Ranges in value from 1 - 19. | column | Integer32 | .1.3.6.1.4.1.7342.1.1.1.1 |
| prodrev The product revision of the module. | column | Integer32 | .1.3.6.1.4.1.7342.1.1.1.10 |
| ledstat The status of any first 32 LEDs on the module, excluding the power LED.
If an LED is missing its number is skipped.
For an eight LED position device the following i… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7342.1.1.1.11 |
| switchstat The status of any DIP switches on the module.
DIP switch 1 is switchstat.0,
DIP switch 2 is switchstat.1,
DIP switch 3 is switchstat.2, etc.
DIP switch bank 1 is sw… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7342.1.1.1.12 |
| extended1 General extended status for the module. Normally this is the
actual setting of the DIP switch selection. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7342.1.1.1.13 |
| extended2 General extended status for the module | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7342.1.1.1.14 |
| extended3 General extended status for the module | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7342.1.1.1.15 |
| extended4 General extended status for the module | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7342.1.1.1.16 |
| extended5 General extended status for the module | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7342.1.1.1.17 |
| extended6 General extended status for the module | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7342.1.1.1.18 |
| resetmod Writing to this variable resets the module. This variable is a write only.
Writing a zero (0) will reboot to the current working application image
W… | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7342.1.1.1.19 |
| slotnum The slot number of the module.
For the 19 slot chassis it ranges in value from 1-22.
For the 2 slot chassis it ranges in value from 1-2. | column | Integer32 | .1.3.6.1.4.1.7342.1.1.1.2 |
| wrswitch Writing to this variable updates the module switch settings.
See switchstat above for the explanation. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.7342.1.1.1.20 |
| modulename The name of the module | column | OctetString | .1.3.6.1.4.1.7342.1.1.1.21 |
| prodtype The product type of the module:
61 = iConverter NMM
64 = iConverter Power Supply (19 Module)
65 = iConverter 10FL/T Ethernet
66 = iConverter 100 Fx/Tx Ethernet
67 = iConverter Fib… | column | Integer32 | .1.3.6.1.4.1.7342.1.1.1.4 |
| chassisname The name of the chassis that is used to set and get names from
other modules in the chassis. | column | OctetString | .1.3.6.1.4.1.7342.1.1.1.5 |
| partnum The part number of the module. | column | OctetString | .1.3.6.1.4.1.7342.1.1.1.6 |
| serialnum The serial number of the module. | column | OctetString | .1.3.6.1.4.1.7342.1.1.1.7 |
| manufdate The date the module was manufactured in form YYYYMMDD. | column | OctetString | .1.3.6.1.4.1.7342.1.1.1.8 |
| softrev The software revision of the module software. | column | Integer32 | .1.3.6.1.4.1.7342.1.1.1.9 |