ostElpsInstanceCfgProtectionType
OMNITRON-G8031-MIB ·
.1.3.6.1.4.1.7342.10.1.3.2.1.23
Object
This object selects the protection type of the ELPS instance.
This object can only be written at row creation time and cannot be
modified once it has been created.
Context
- MIB
- OMNITRON-G8031-MIB
- OID
.1.3.6.1.4.1.7342.10.1.3.2.1.23- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ostElpsInstanceCfgEntry
- Table
- ostElpsInstanceCfgTable
- Siblings
- 26
Syntax
OMNITRON-TC-MIBOstElpsProtectType
- Source
- OMNITRON-TC-MIBOstElpsProtectType
- Base type
Enumeration
Values & Constraints
Type Values
1 | e1plus1UniNoAps |
2 | e1plus1UniAps |
3 | e1plus1BiAps |
4 | e1to1 |
5 | notAvailable |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ostElpsInstanceCfgIndex An index to the ELPS Instance Configuration table which indicates
the specific ELPS instance for the module.
ostElpsGlobalCfgNextIndex needs to be inspected to find… | column | Unsigned32 | .1.3.6.1.4.1.7342.10.1.3.2.1.1 |
| ostElpsInstanceCfgWaitToRestoreTime This object specifies the wait to restore time in minutes.
This object can be written/modified after row creation time. | column | Unsigned32 | .1.3.6.1.4.1.7342.10.1.3.2.1.10 |
| ostElpsInstanceCfgApsRate This object specifies the time between APS frames in seconds.
This object is only used when the APS frame transmission is enabled.
This object can be… | column | Unsigned32 | .1.3.6.1.4.1.7342.10.1.3.2.1.11 |
| ostElpsInstanceCfgApsToSend This object specifies the number of APS frames to send that are
separated by a minimum delay when a protection switch occurs.
This object is only used when the APS … | column | Unsigned32 | .1.3.6.1.4.1.7342.10.1.3.2.1.12 |
| ostElpsInstanceCfgScopeType This object selects the specific scope type of the ELPS instance.
port(1) ELPS instance is port based
evc(2) ELPS instance is EVC based
mep(3) E… | column | Enumeration | .1.3.6.1.4.1.7342.10.1.3.2.1.13 |
| ostElpsInstanceCfgEvc This object defines which EVC the ELPS instance is associated with.
It must be configured if ostElpsInstanceCfgScopeType is 'evc', 'mep'.
It is ignored for other instance types.
… | column | OMNITRON-TC-MIBOstEvcNameStringOrNone | .1.3.6.1.4.1.7342.10.1.3.2.1.14 |
| ostElpsInstanceCfgVid This object defines which specific VID the ELPS instance is associated
with. It is deprecated and should not be used.
This object can only be written at row creatio… | column | OMNITRON-TC-MIBOstVlanId | .1.3.6.1.4.1.7342.10.1.3.2.1.15 |
| ostElpsInstanceCfgPriority This object specifies the ELPS instance PCP value (tag priority) on
the generated APS PDU.
This object can only be written at row creation time and cannot be
modifi… | column | IEEE8021-TC-MIBIEEE8021PriorityValue | .1.3.6.1.4.1.7342.10.1.3.2.1.16 |
| ostElpsInstanceCfgWorkingMdIndex This object specifies the Working MEP ELPS instance maintenance
domain index.
The value is ignored for ostElpsInstanceCfgScopeType 'port' or 'evc'.
I… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7342.10.1.3.2.1.17 |
| ostElpsInstanceCfgWorkingMaIndex This object specifies the Working MEP ELPS instance maintenance
association index.
It is mandatory to be configured with a valid value if
ostElpsInstanceCfgScopeTyp… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7342.10.1.3.2.1.18 |
| ostElpsInstanceCfgWorkingMepId This object specifies the Working MEP ELPS instance Maintenance End
Point Identifier.
It is mandatory to be configured with a valid value if
ostElpsInstanceCfgScope… | column | IEEE8021-CFM-MIBDot1agCfmMepIdOrZero | .1.3.6.1.4.1.7342.10.1.3.2.1.19 |
| ostElpsInstanceCfgRowStatus The status of the row.
The writable columns in a row cannot be changed if the row
is active. All columns must have a valid value before a row
can be activated. | column | SNMPv2-TCRowStatus | .1.3.6.1.4.1.7342.10.1.3.2.1.2 |
| ostElpsInstanceCfgProtectionMdIndex This object specifies the Protection MEP ELPS instance maintenance
domain index.
The value is ignored for ostElpsInstanceCfgScopeType 'port' or 'evc'.
… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7342.10.1.3.2.1.20 |
| ostElpsInstanceCfgProtectionMaIndex This object specifies the Protection MEP ELPS instance maintenance
association index.
It is mandatory to be configured with a valid value if
ostElpsInstanceCfgScope… | column | SNMPv2-SMIUnsigned32 | .1.3.6.1.4.1.7342.10.1.3.2.1.21 |
| ostElpsInstanceCfgProtectionMepId This object specifies the Protection MEP ELPS instance Maintenance End
Point Identifier.
It is mandatory to be configured with a valid value if
ostElpsInstanceCfgSc… | column | IEEE8021-CFM-MIBDot1agCfmMepIdOrZero | .1.3.6.1.4.1.7342.10.1.3.2.1.22 |
| ostElpsInstanceCfgRevertive This object specifies whether the ELPS instance is revertive or
non-revertive. Revertive indicates whether the working link becomes
active after it is restored.
The… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.7342.10.1.3.2.1.24 |
| ostElpsInstanceCfgManualMode This object selects the protection instance manual mode. When written the
indicated manual mode is selected.
nocommand(0) no command is indicated, read-only value… | column | Enumeration | .1.3.6.1.4.1.7342.10.1.3.2.1.25 |
| ostElpsInstanceCfgClearStatistics This object when written clears the statistic counters associated with
a specific protection instance. When read the value always returns
'false'.
Writing this valu… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.7342.10.1.3.2.1.26 |
| ostElpsInstanceCfgEvcProtected This object defines which EVC the protected ELPS port is
associated with. If uninitialized (null length string) or is the same
value as ostElpsInstanceCfgEvc then this object indi… | column | OMNITRON-TC-MIBOstEvcNameStringOrNone | .1.3.6.1.4.1.7342.10.1.3.2.1.27 |
| ostElpsInstanceCfgProfileEnable This object specifies whether the ELPS profile is enabled for
the ELPS instance.
The value 'true' indicates the ELPS profile instance is enabled.
The… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.7342.10.1.3.2.1.3 |
| ostElpsInstanceCfgHoldOffEnable This object specifies whether the ELPS holdoff function is
enabled for the ELPS instance.
The value 'true' indicates the ELPS holdoff instance function is
enabled.
… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.7342.10.1.3.2.1.4 |
| ostElpsInstanceCfgWaitToRestoreEnable This object specifies whether the ELPS wait to restore function is
enabled for the ELPS instance.
The value 'true' indicates the ELPS wait to restore instance funct… | column | SNMPv2-TCTruthValue | .1.3.6.1.4.1.7342.10.1.3.2.1.5 |
| ostElpsInstanceCfgProtectionName ELPS instance profile name.
This object may not be modified after creation. | column | OMNITRON-TC-MIBOstProfileNameString | .1.3.6.1.4.1.7342.10.1.3.2.1.6 |
| ostElpsInstanceCfgProtectionPortNumber This object selects the protection port number for the specific ELPS
instance that is configured.
This object can only be written at row creation time and cannot be… | column | OMNITRON-TC-MIBOstPortNumber | .1.3.6.1.4.1.7342.10.1.3.2.1.7 |
| ostElpsInstanceCfgWorkingPortNumber This object selects the working port number for the specific ELPS
instance that is configured.
This object can only be written at row creation time and cannot be
mo… | column | OMNITRON-TC-MIBOstPortNumber | .1.3.6.1.4.1.7342.10.1.3.2.1.8 |
| ostElpsInstanceCfgHoldOffTime This object specifies the hold-off time in 0.1 seconds.
A value of 0 indicates there is no hold-off time.
This object can be written/modified after r… | column | Unsigned32 | .1.3.6.1.4.1.7342.10.1.3.2.1.9 |