ostEnetStInitCfgPriority

OMNITRON-EST-MIB · .1.3.6.1.4.1.7342.10.1.1.2.1.12

Object

column r/w IEEE8021-TC-MIBIEEE8021PriorityValue
This object specifies the test instance PCP value (tag priority) on
the generated test PDU.
              
It must be configured if ostEnetStInitCfgType 'evc' or 'evccos'
and if the EVC is a tagged type of data.
              
If ostEnetStInitCfgType is 'evccos' it is the only PCP value that the
test instance is associated with. Other PCP values will not be
examined or counted.
              
If ostEnetStInitCfgType is 'evc', 'lbm' or 'tst' this value is only used
when the test instance PDU is generated, and the frame is tagged, but will
not be examined when the test response PDUs are received.
              
This object can only be written at row creation time and cannot be
modified once it has been created.

Context

MIB
OMNITRON-EST-MIB
OID
.1.3.6.1.4.1.7342.10.1.1.2.1.12
Type
column
Access
readwrite
Status
current
Parent
ostEnetStInitCfgEntry
Table
ostEnetStInitCfgTable
Siblings
57

Syntax

IEEE8021-TC-MIBIEEE8021PriorityValue
Source
IEEE8021-TC-MIBIEEE8021PriorityValue
Base type
Unsigned32

Values & Constraints

Type Constraints
range: 0..7

Related Objects

Sibling Objects