batterySensorErrorStatus
NetBotz50-MIB ·
.1.3.6.1.4.1.52674.500.4.1.14.1.3
Object
column
ErrorStatus
The operational status of the sensor. If there are no error conditions reported for the sensor, the status is normal. Otherwise, the status is reported as the severity value of the highest severity error condition that is not resolved for the sensor.
Context
- MIB
- NetBotz50-MIB
- OID
.1.3.6.1.4.1.52674.500.4.1.14.1.3- Type
- column
- Access
- readonly
- Status
- current
- Parent
- batterySensorEntry
- Table
- batterySensorTable
- Siblings
- 11
Syntax
ErrorStatus
- Source
- ErrorStatus
- Base type
Enumeration
Values & Constraints
Type Values
0 | normal |
1 | info |
2 | warning |
3 | error |
4 | critical |
5 | failure |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| batterySensorId The unique id of the sensor. | column | OctetString | .1.3.6.1.4.1.52674.500.4.1.14.1.1 |
| batterySensorValueIntX1000 The value measured by the sensor in thousandths of the unit of measure (100 times batterySensorValue) | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.52674.500.4.1.14.1.10 |
| batterySensorValueIntX1000000 The value measured by the sensor in millionths of the unit of measure (100000 times batterySensorValue) | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.52674.500.4.1.14.1.11 |
| batterySensorIndex The index of the sensor. | column | SNMPv2-SMICounter32 | .1.3.6.1.4.1.52674.500.4.1.14.1.12 |
| batterySensorValue The value measured by the sensor in tenths of the unit of measure. | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.52674.500.4.1.14.1.2 |
| batterySensorLabel The unique label assigned to the sensor. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.52674.500.4.1.14.1.4 |
| batterySensorEncId The id of the physical enclosure containing the sensor. | column | OctetString | .1.3.6.1.4.1.52674.500.4.1.14.1.5 |
| batterySensorPortId The id of the port the sensor is plugged into (or empty string
if it is not plugged into a port). | column | OctetString | .1.3.6.1.4.1.52674.500.4.1.14.1.6 |
| batterySensorValueStr The sensor reading shown as a string (or empty string
if it is not plugged into a port). | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.52674.500.4.1.14.1.7 |
| batterySensorValueInt The value measured by the sensor in the unit of measure (1/10 of batterySensorValue) | column | SNMPv2-SMIInteger32 | .1.3.6.1.4.1.52674.500.4.1.14.1.8 |
| batterySensorUnits The unit of measure for the sensor value. | column | SNMPv2-TCDisplayString | .1.3.6.1.4.1.52674.500.4.1.14.1.9 |