ifCfgPortAdslFrameType
NTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB ·
.1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.7
Object
column
r/w
Enumeration
ADSL frame type.
Context
- MIB
- NTNTECH-INTERFACE-MODULE-CONFIGURATION-MIB
- OID
.1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.7- Type
- column
- Access
- readwrite
- Status
- current
- Parent
- ifCfgPortAdslEntry
- Table
- ifCfgPortAdslTable
- Siblings
- 22
Syntax
Enumeration
Values & Constraints
Enumerated Values
1 | frameType1483LLC |
2 | frameType1483VCM |
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| ifCfgAdslSlotIndex The physical slot number of the IPD chassis to which the interface module
resides. The Mini/Micro slot index will be 1. | column | Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.1 |
| ifCfgPortAdslStandardMde ADSL standard modes of operation.
Note: if receive a standard mode of integer value 255 (0xFF), this would
indicate that the standard mode is unknown due to … | column | Enumeration | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.10 |
| ifCfgPortAdslCorrectionUp ADSL Impulse protection duration in the Upstream duration. | column | Enumeration | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.11 |
| ifCfgPortAdslCorrectionDn ADSL Impulse protection duration in the Upstream duration. | column | Enumeration | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.12 |
| ifCfgPortAdslDelayUp ADSL Impulse protection duration in the Upstream direction. | column | Enumeration | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.13 |
| ifCfgPortAdslDelayDn ADSL Impulse protection duration in the Upstream direction. | column | Enumeration | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.14 |
| ifCfgPortAdslEcFdm ADSL Echo Cancellation uses Upstream Tones for Upstream and Dnstream data. | column | Enumeration | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.15 |
| ifCfgPortAdslFastBuffer Selects fast buffer/low latency. Same is interleave delay of 1ms | column | Enumeration | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.16 |
| ifCfgPortAdslSnrUp Selects Target Upstream SNR | column | Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.17 |
| ifCfgPortAdslSnrDn Selects Target Dnstream SNR | column | Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.18 |
| ifCfgPortAdslActualRxRate ADSL upstream (Rx) data rate.
The available upstream data rates range from 32Kbps to 1024Kbps.
The upstream data rate can be set by the user via the set value… | column | Kbps Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.19 |
| ifCfgAdslPortIndex The physical port number of the ADSL interface. | column | Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.2 |
| ifCfgPortAdslActualTxRate ADSL downstream (Tx) data rates.
The available downstream data rates range from 32Kbps to 8064Kbps.
The downstream data rate can be set by the user via the set va… | column | Kbps Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.20 |
| ifCfgPortAdslActualStandardMde ADSL current operating mode, should match ifCfgPortAdslStandardMde UNLESS operating in MULTIMODE | column | Enumeration | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.21 |
| ifCfgPortAdslActualDepthUp ADSL upstream interleving depth. | column | Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.22 |
| ifCfgPortAdslActualDepthDn ADSL dnstream interleaving depth. | column | Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.23 |
| ifCfgPortAdslPortMode The port mode of operation, ON, OFF, or Adaptive.
When a port is set to Adaptive mode, the best possible value for the
Rx/Tx data rates will be achieved. A success… | column | Enumeration | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.3 |
| ifCfgPortAdslVpiVciDetect ADSL Virtual Path Identifier (VPI) and Virtual Channel Identifier
(VCI) detect mode. If this mode is set to ON, auto-detect the line
VPI and VCI values. | column | Enumeration | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.4 |
| ifCfgPortAdslRxRate ADSL upstream (Rx) data rate.
The available upstream data rates range from 32Kbps to 1024Kbps.
The upstream data rate can be set by the user via the set value… | column | Kbps Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.5 |
| ifCfgPortAdslTxRate ADSL downstream (Tx) data rates.
The available downstream data rates range from 32Kbps to 8064Kbps.
The downstream data rate can be set by the user via the set va… | column | Kbps Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.6 |
| ifCfgPortAdslVpi ADSL Virtual Path Identifier (VPI) value. | column | Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.8 |
| ifCfgPortAdslVci ADSL Virtual Channel Identifier (VCI). | column | Integer32 | .1.3.6.1.4.1.8059.1.2.1.1.1.2.3.1.9 |