upsControl
NEXT-UPS-MIB ·
.0.1.1.8
Object
node
No description available.
Context
- MIB
- NEXT-UPS-MIB
- OID
.0.1.1.8- Type
- node
- Parent
- ups
- Siblings
- 12
- Children
- 10
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsIdent | node | - | .0.1.1.1 |
| commConfig | node | - | .0.1.1.10 |
| upsConfig | node | - | .0.1.1.11 |
| upsTraps | node | - | .0.1.1.12 |
| extend | node | - | .0.1.1.13 |
| upsRating | node | - | .0.1.1.2 |
| upsBattery | node | - | .0.1.1.3 |
| upsInput | node | - | .0.1.1.4 |
| upsOutput | node | - | .0.1.1.5 |
| upsBypass | node | - | .0.1.1.6 |
| upsTest | node | - | .0.1.1.7 |
| agentConfig | node | - | .0.1.1.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| upsCtlShutdownDelay The delay in seconds the UPS remains on after being told
to turn off. if value=-2 cancel shutdown, if value=-1 donothing,
value=0 shutdown ups immediately | scalar | seconds Integer32 | .0.1.1.8.1 |
| upsCtlResetConfigure reset all configure para to default. | scalar | Enumeration | .0.1.1.8.10 |
| upsCtlSleepTime The time in minutes for the UPS to go to sleep when
instructed. When in sleep mode, the UPS will not provide
output power regardless of the input line state. Once the
specified… | scalar | minutes Integer32 | .0.1.1.8.2 |
| upsCtlStartupAfterDelay Setting this object will start the output after the
indicated number of seconds, including starting the
UPS, if necessary. -1 mean not startup.
must set upsCtlStartupAfterDela… | scalar | seconds Integer32 | .0.1.1.8.3 |
| upsCtlbuzzer Setting this object to 'on' or 'off' to enable or disable buzzer | scalar | Enumeration | .0.1.1.8.4 |
| upsCtlRemoteControlUPS Setting this object to turn 'on' or 'off' UPS | scalar | Enumeration | .0.1.1.8.5 |
| upsCtloutletPoweron Setting this object to 1 means 1st outlet,2 means 2nd outlet , immediately process | scalar | Integer32 | .0.1.1.8.6 |
| upsCtloutletPoweroff Setting this object to 1 means 1st outlet,
2 means 2nd outlet , immediately process | scalar | Integer32 | .0.1.1.8.7 |
| upsCtlOutlet1Powerofftime setting this object to -1 means this control not effect,
0 means immediately process,
>0 means wait times unit is minutes
use in battery mode | scalar | Integer32 | .0.1.1.8.8 |
| upsCtlOutlet2Powerofftime setting this object to -1 means this control not effect,
0 means immediately process ,
>0 means wait times unit is minutes .use in battery mode | scalar | Integer32 | .0.1.1.8.9 |