solarConfig
NEXT-UPS-MIB ·
.0.1.2.14
Object
node
No description available.
Context
- MIB
- NEXT-UPS-MIB
- OID
.0.1.2.14- Type
- node
- Parent
- inverter
- Siblings
- 15
- Children
- 34
Syntax
No syntax metadata recorded.
Values & Constraints
No enumerated values or constraints recorded.
Related Objects
Sibling Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| solarIdent | node | - | .0.1.2.1 |
| solarFaultInfo | node | - | .0.1.2.10 |
| solarControl | node | - | .0.1.2.11 |
| solarAgentConfig | node | - | .0.1.2.12 |
| solarCommConfig | node | - | .0.1.2.13 |
| solarTraps | node | - | .0.1.2.15 |
| solarExtend | node | - | .0.1.2.16 |
| solarRating | node | - | .0.1.2.2 |
| solarBattery | node | - | .0.1.2.3 |
| solarGrid | node | - | .0.1.2.4 |
| solarACOutput | node | - | .0.1.2.5 |
| solarPV | node | - | .0.1.2.6 |
| solarEnergy | node | - | .0.1.2.7 |
| solarTest | node | - | .0.1.2.8 |
| solarDefValue | node | - | .0.1.2.9 |
Child Objects
| Object | Type | Syntax | OID |
|---|---|---|---|
| solarCfgGridOutVolHLoss grid output voltage high loss point | scalar | 0.1 Volts Integer32 | .0.1.2.14.1 |
| solarCfgGridInVolHLoss Set grid input voltage high loss point | scalar | 0.1 V Integer32 | .0.1.2.14.11 |
| solarCfgGridInVolLLoss Set grid input voltage low loss point | scalar | 0.1 V Integer32 | .0.1.2.14.12 |
| solarCfgGridInFreqHLoss grid input frequency high loss point | scalar | 0.1Hz Integer32 | .0.1.2.14.13 |
| solarCfgGridInFreqLLoss grid input frequency low loss point | scalar | 0.1Hz Integer32 | .0.1.2.14.14 |
| solarCfgAverageVolHLoss the grid long time average voltage high loss point | scalar | 0.1V Integer32 | .0.1.2.14.15 |
| solarCfgAverageVolLLoss the grid long time average voltage low loss point | scalar | 0.1V Integer32 | .0.1.2.14.16 |
| solarCfgSetDefaultValue Setting control parsameter to default valuse | scalar | Enumeration | .0.1.2.14.17 |
| solarCfgWaiteTimeFeed Setting waiting time for feeding | scalar | second Integer32 | .0.1.2.14.18 |
| solarCfgSilenceBuzzer Setting this object to Enable/disable silence buzzer or open buzzer | scalar | Enumeration | .0.1.2.14.19 |
| solarCfgGridOutVolLLoss grid output voltage low loss point | scalar | 0.1 Volts Integer32 | .0.1.2.14.2 |
| solarCfgBuzzerInStandby Setting this object to Enable/disable buzzer audible in standby mode | scalar | Enumeration | .0.1.2.14.20 |
| solarCfgAutoRestart Enable/disable auto-Restart. (for hybrid) | scalar | Enumeration | .0.1.2.14.21 |
| solarCfgBatMAudibleWarn Enable/disable battery mode audible warning (for hybrid) | scalar | Enumeration | .0.1.2.14.22 |
| solarCfgBatOpenCheck Enable/disable battery open status check (for hybrid) | scalar | Enumeration | .0.1.2.14.23 |
| solarCfgSiteFaultDetect Enable/disable Site fault detect (for hybrid) | scalar | Enumeration | .0.1.2.14.24 |
| solarCfgHotStandbyMS Hot standby master/slave PEM means master, PDM means slave (for hybrid) | scalar | Enumeration | .0.1.2.14.25 |
| solarCfgBatDpDischgProt Enable/disable battery deep discharge protect (for hybrid) | scalar | Enumeration | .0.1.2.14.26 |
| solarCfgBatLowDischgProt Enable/disable battery low protect (if disable, the battery will discharge to 6V) (for hybrid) | scalar | Enumeration | .0.1.2.14.27 |
| solarCfgCodeStart Enable/disable code start (for hybrid) | scalar | Enumeration | .0.1.2.14.28 |
| solarCfgBypassForbid Enable/disable bypass forbidding (for hybrid) | scalar | Enumeration | .0.1.2.14.29 |
| solarCfgGridOutFreqHLoss grid output frequency high loss point | scalar | 0.1 Hertz Integer32 | .0.1.2.14.3 |
| solarCfgBypassWhenOff Enable/disable bypass when device turn off. (for hybrid) | scalar | Enumeration | .0.1.2.14.30 |
| solarCfgShortRestart3 Enable/disable short restart 3 times (for hybrid) | scalar | Enumeration | .0.1.2.14.31 |
| solarCfgShortClear Enable/disable inverter short clear function (for hybrid) | scalar | Enumeration | .0.1.2.14.32 |
| solarCfgMaxChargeVol Max floating charging voltage (for hybrid) | scalar | 0.1V Integer32 | .0.1.2.14.33 |
| solarCfgMaxChargeCurr Max floating charging current (for hybrid) | scalar | 0.1A Integer32 | .0.1.2.14.34 |
| solarCfgChargingEnable Enable/disable charging on grid mode (for hybrid) | scalar | Enumeration | .0.1.2.14.35 |
| solarCfgGridOutFreqLLoss grid output frequency low loss point | scalar | 0.1 Hertz Integer32 | .0.1.2.14.4 |
| solarCfgCurrentMaxOutPower the max output power.
ener solar:0-030000 | scalar | 0.1 W Integer32 | .0.1.2.14.5 |
| solarCfgPVHVolMPPT the PV input high voltage for MPPT | scalar | 0.1 V Integer32 | .0.1.2.14.6 |
| solarCfgPVLVolMPPT Set the PV input low voltage for MPPT | scalar | 0.1 V Integer32 | .0.1.2.14.7 |
| solarCfgUpLimitPVVol Set the upper limit of PV input voltage | scalar | 0.1 V Integer32 | .0.1.2.14.8 |
| solarCfgLowLimitPVVol Set the lowest limit of PV input voltage | scalar | 0.1 V Integer32 | .0.1.2.14.9 |